Your browser doesn't support javascript.
loading
Systematic Comparison of Uremic Toxin Removal Using Different Hemodialysis Modes: A Single-Center Crossover Prospective Observational Study.
Duval-Sabatier, Ariane; Burtey, Stephane; Pelletier, Marion; Laforet, Manon; Dou, Laetitia; Sallee, Marion; Lorec, Anne-Marie; Knidiri, Hafssa; Darbon, Floriane; Berland, Yvon; Brunet, Philippe.
Afiliação
  • Duval-Sabatier A; Centre de Néphrologie et Transplantation Rénale, Assistance-Publique-Hôpitaux de Marseille, Hôpital de la Conception 147 Bd Baille, 13005 Marseille, France.
  • Burtey S; INSERM, C2VN, INRA, Aix Marseille University, 13005 Marseille, France.
  • Pelletier M; Association des Dialysés Provence et Corse ADPC, 13008 Marseille, France.
  • Laforet M; Centre de Néphrologie et Transplantation Rénale, Assistance-Publique-Hôpitaux de Marseille, Hôpital de la Conception 147 Bd Baille, 13005 Marseille, France.
  • Dou L; INSERM, C2VN, INRA, Aix Marseille University, 13005 Marseille, France.
  • Sallee M; Centre de Néphrologie et Transplantation Rénale, Assistance-Publique-Hôpitaux de Marseille, Hôpital de la Conception 147 Bd Baille, 13005 Marseille, France.
  • Lorec AM; INSERM, C2VN, INRA, Aix Marseille University, 13005 Marseille, France.
  • Knidiri H; Centre de Néphrologie et Transplantation Rénale, Assistance-Publique-Hôpitaux de Marseille, Hôpital de la Conception 147 Bd Baille, 13005 Marseille, France.
  • Darbon F; INSERM, C2VN, INRA, Aix Marseille University, 13005 Marseille, France.
  • Berland Y; INSERM, C2VN, INRA, Aix Marseille University, 13005 Marseille, France.
  • Brunet P; Centre de Néphrologie et Transplantation Rénale, Assistance-Publique-Hôpitaux de Marseille, Hôpital de la Conception 147 Bd Baille, 13005 Marseille, France.
Biomedicines ; 11(2)2023 Jan 27.
Article em En | MEDLINE | ID: mdl-36830910
ABSTRACT
Many hypotheses could explain the mortality decrease observed using hemodiafiltration, such as reduction of intradialytic hypotension and more efficient toxin removal. We led a systematic analysis of representative uremic toxin removal with hemodialysis (HD), online postdilution hemodiafiltration (postHDF) and online predilution hemodiafiltration (preHDF), in a single-center crossover and prospective observational study. The primary outcome was the reduction ratio of uremic toxins of the three categories defined by the Eutox group. Twenty-six patients were treated by those three techniques of extra renal epuration. Mean Kt/Vurea was not different between the treatment methods. Mean reduction ratio of beta2microglobulin was significantly higher for both HDF treatments than for HD (p < 0.001). Myoglobin, kappa, and lambda free light chain reduction ratio was significantly different between the modes 37.75 ± 11.95%, 45.31 ± 11% and 61.22 ± 10.56%/57.21 ± 12.5%, 63.53 ± 7.93%, and 68.40 ± 11.79%/29.12 ± 8.44%, 34.73 ± 9.01%, and 45.55 ± 12.31% HD, preHDF, and postHDF, respectively (p < 0.001). Mean protein-bound solutes reduction ratio was not different between the different treatments except for PCS with a higher reduction ratio during HDF treatments. Mean albumin loss was always less than 2 g. HDF improved removal of middle molecules but had no effect on indoles concentration without any difference between synthetic dialysis membranes.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Observational_studies Idioma: En Revista: Biomedicines Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Observational_studies Idioma: En Revista: Biomedicines Ano de publicação: 2023 Tipo de documento: Article