Repair of a Late Presentation Thoracic Aortic Aneurysm following Coarctation Repair.
Moon, Robert J; Spadaccio, Cristiano; Duncan, Andrew J; Bittar, Mohamad N.
Afiliação
  • Moon RJ; Department of Cardiothoracic Surgery, Lancashire Cardiac Centre, Blackpool Victoria Hospital, Blackpool, United Kingdom.
  • Spadaccio C; Department of Cardiothoracic Surgery, Lancashire Cardiac Centre, Blackpool Victoria Hospital, Blackpool, United Kingdom.
  • Duncan AJ; Department of Cardiothoracic Surgery, Lancashire Cardiac Centre, Blackpool Victoria Hospital, Blackpool, United Kingdom.
  • Bittar MN; Department of Cardiothoracic Surgery, Lancashire Cardiac Centre, Blackpool Victoria Hospital, Blackpool, United Kingdom.
Aorta (Stamford) ; 11(1): 44-46, 2023 Feb.
Article em En | MEDLINE | ID: mdl-36848912
ABSTRACT
We report the case of a 44-year-old gentleman who underwent coarctation repair at the age of 7 years. He was lost to follow-up and represented. Computed tomography scan demonstrated a 9.8-cm diameter aortic aneurysm involving the distal aortic arch and proximal descending aorta. Open surgery was performed to repair the aneurysm. The patient made an unremarkable recovery. He was followed up 12 weeks later, and significant improvement in preoperative symptoms was observed. This case demonstrates the importance of long-term follow-up.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Aorta (Stamford) Ano de publicação: 2023 Tipo de documento: Article