Your browser doesn't support javascript.
loading
In Vivo Postoperative Motion of Fixed and Mobile Medial Pivot Knees Under Weight-Bearing Conditions after Cruciate-Sacrificing Total Knee Arthroplasty.
Yoshioka, Toru; Okimoto, Nobukazu; Sawa, Mikiya; Asano, Kei; Obayashi, Kenji; Kawasaki, Makoto; Majima, Tokifumi.
Afiliação
  • Yoshioka T; Department of Orthopaedic Surgery, Shimura Hospital.
  • Okimoto N; Department of Orthopaedic Surgery, Shimura Hospital.
  • Sawa M; Okimoto Clinic.
  • Asano K; Department of Orthopaedic Surgery, Shimura Hospital.
  • Obayashi K; Department of Orthopaedic Surgery, Shimura Hospital.
  • Kawasaki M; Department of Orthopaedic Surgery, Shimura Hospital.
  • Majima T; Department of Orthopaedic Surgery, University of Occupational and Environmental Health.
J Nippon Med Sch ; 90(1): 103-110, 2023.
Article em En | MEDLINE | ID: mdl-36908123
BACKGROUND: In vivo three-dimensional (3D) motion under weight-bearing conditions was analyzed postoperatively in medial pivot cruciate-substituting (CS) knee systems with fixed and mobile inserts. METHODS: Tibiofemoral knee kinematics during squatting were captured with X-ray fluoroscopy for 4 patients in each cohort. The 3D motion of implants was analyzed with KneeMotion motion analysis software (LEXI Corporation; Tokyo, Japan). In addition, anterior-posterior (AP) movement of the distal-most points and the angle of axial rotation of the femoral component on the tibial component were assessed in both cohorts. RESULTS: Mean AP movement of the femoral component on the tibial component was 3.8±0.5 mm on the medial side and 9.5±0.5 mm on the lateral side in the cohort with fixed prostheses and 5.9±2.1 mm on the medial side and 10.0±2.5 mm on the lateral side in the cohort with mobile prostheses. The mean angle of axial rotation of the femoral component on the tibial component was 14.4±1.1 degrees and 8.2±2.7 degrees of external rotation for fixed knees and mobile knees, respectively. CONCLUSIONS: Postoperative motion analysis confirmed that fixed and mobile CS implants, which have a similar design, guided medial pivot motion under weight-bearing conditions. However, motion differed between these implant types after mid-flexion: bicondylar rollback after medial pivot motion was noted in the mobile cohort.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Artroplastia do Joelho / Prótese do Joelho Limite: Humans Idioma: En Revista: J Nippon Med Sch Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Artroplastia do Joelho / Prótese do Joelho Limite: Humans Idioma: En Revista: J Nippon Med Sch Ano de publicação: 2023 Tipo de documento: Article