Your browser doesn't support javascript.
loading
The effect of high-irradiance rapid polymerization on degree of conversion, monomer elution, polymerization shrinkage and porosity of bulk-fill resin composites.
Lempel, Edina; Szebeni, Donát; Ori, Zsuzsanna; Kiss, Tamás; Szalma, József; Lovász, Bálint Viktor; Kunsági-Máté, Sándor; Böddi, Katalin.
Afiliação
  • Lempel E; Department of Restorative Dentistry and Periodontology, University of Pécs Medical School, Tüzér Street 1, Pécs 7623, Hungary. Electronic address: lempel.edina@pte.hu.
  • Szebeni D; Department of Restorative Dentistry and Periodontology, University of Pécs Medical School, Tüzér Street 1, Pécs 7623, Hungary.
  • Ori Z; János Szentágothai Research Center, Ifjúság Street 12, Pécs 7624, Hungary; Department of General and Physical Chemistry, University of Pécs, Ifjúság Street 6, Pécs 7624, Hungary.
  • Kiss T; János Szentágothai Research Center, Ifjúság Street 12, Pécs 7624, Hungary.
  • Szalma J; Department of Oral and Maxillofacial Surgery, University of Pécs Medical School, Tüzér Street 1, Pécs 7623, Hungary.
  • Lovász BV; Department of Oral and Maxillofacial Surgery, University of Pécs Medical School, Tüzér Street 1, Pécs 7623, Hungary.
  • Kunsági-Máté S; János Szentágothai Research Center, Ifjúság Street 12, Pécs 7624, Hungary; Department of Organic and Medicinal Chemistry, University of Pécs, Faculty of Pharmacy, Honvéd Street 1, Pécs 7624, Hungary.
  • Böddi K; Department of Biochemistry and Medical Chemistry, University of Pécs Medical School, Szigeti Street 12, Pécs 7624, Hungary.
Dent Mater ; 39(4): 442-453, 2023 04.
Article em En | MEDLINE | ID: mdl-36918332
ABSTRACT

OBJECTIVE:

The purpose was to compare the degree of conversion (DC), monomer elution (ME), polymerization shrinkage (PS) and porosity of two addition-fragmentation chain transfer (AFCT) modified resin-based composites (RBC) light-cured with rapid- (RP), turbo- (TP) or conventional polymerization (CP) settings.

METHODS:

Cylindrical samples (6-mm wide, 4-mm thick) were prepared from Tetric PowerFill (TPF) and Filtek One Bulk (FOB). Four groups were established according to the polymerization settings 3s-RP, 5s-TP, 10s-CP and 20s-CP. Samples in 1 mm thickness with 20s-CP settings served as controls. The DC at the top and bottom surfaces was measured with micro-Raman spectroscopy. ME was detected with high-performance liquid chromatography. PS and porosity were analyzed by micro-computed tomography. ANOVA and Tukey's post-hoc test, multivariate analysis and partial eta-squared statistics were used to analyze the data (p < 0.05).

RESULTS:

FOB showed higher DC values (61.5-77.5 %) at the top compared to TPF (43.5-67.8 %). At the bottom TPF samples achieved higher DCs (39.9-58.5 %) than FOB (18.21-66.18 %). Extending the curing time increased DC (except the top of FOB) and decreased ME. BisGMA release was the highest among the detected monomers from both RBCs. The amount was three-fold more from TPF. The factor Material and Exposure significantly influenced DC and ME. PS (1.8-2.5 %) did not differ among the groups and RBCs except for the lowest value of TPF cured with the 3s_RP setting (p = 0.03). FOB showed 4.5-fold lower porosity (p < 0.001). Significantly higher pore volume was detected after polymerization in 3s_RP (p < 0.001).

SIGNIFICANCE:

High-irradiance rapid 3-s curing of AFCT modified RBCs resulted in inferior results for some important material properties. A longer exposure time is recommended in a clinical situation.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Resinas Compostas / Materiais Dentários Idioma: En Revista: Dent Mater Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Resinas Compostas / Materiais Dentários Idioma: En Revista: Dent Mater Ano de publicação: 2023 Tipo de documento: Article