Your browser doesn't support javascript.
loading
The usefulness of three-dimensional fusion imaging of spinal arteriovenous malformation by a workstation connected to angiography systems.
Nagashima, Yoshitaka; Izumi, Takashi; Nishimura, Yusuke; Nishihori, Masahiro; Oyama, Takahiro; Matsuo, Mamoru; Ito, Hiroshi; Nishii, Tomoya; Saito, Ryuta.
Afiliação
  • Nagashima Y; Department of Neurosurgery, Nagoya University Graduate School of Medicine, Nagoya, Japan.
  • Izumi T; Department of Neurosurgery, Nagoya University Graduate School of Medicine, Nagoya, Japan.
  • Nishimura Y; Department of Neurosurgery, Nagoya University Graduate School of Medicine, Nagoya, Japan.
  • Nishihori M; Department of Neurosurgery, Nagoya University Graduate School of Medicine, Nagoya, Japan.
  • Oyama T; Department of Neurosurgery, Nagoya University Graduate School of Medicine, Nagoya, Japan.
  • Matsuo M; Department of Neurosurgery, Nagoya University Graduate School of Medicine, Nagoya, Japan.
  • Ito H; Department of Neurosurgery, Nagoya University Graduate School of Medicine, Nagoya, Japan.
  • Nishii T; Department of Neurosurgery, Nagoya University Graduate School of Medicine, Nagoya, Japan.
  • Saito R; Department of Neurosurgery, Nagoya University Graduate School of Medicine, Nagoya, Japan.
Nagoya J Med Sci ; 85(1): 127-133, 2023 Feb.
Article em En | MEDLINE | ID: mdl-36923621
ABSTRACT
Digital subtraction angiography (DSA) is the most useful technique for diagnosing spinal arteriovenous malformations (AVM). In recent years, with the improvement of imaging capabilities, the usefulness of three-dimensional (3D) imaging by fusing various modalities has been recognized. The use of 3D fusion imaging with a workstation connected to an angiography system has been reported in many cases of intracranial disease, but less frequently for spinal AVM. In this article, we describe two illustrative cases of spinal AVM in which 3D fusion imaging was useful for treatment. Although 3D fusion images using the system have the disadvantage that only a maximum of two images can be fused, it provides spinal surgeons with useful information for preoperative evaluation in a small amount of time.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Malformações Arteriovenosas Intracranianas Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: Nagoya J Med Sci Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Malformações Arteriovenosas Intracranianas Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: Nagoya J Med Sci Ano de publicação: 2023 Tipo de documento: Article