Your browser doesn't support javascript.
loading
Ultrasensitive determination of ß-conglutin food allergen by means an aptamer assay based on inductively coupled plasma mass spectrometry detection.
Torregrosa, Daniel; Jauset-Rubio, Miriam; Serrano, Raquel; Svobodová, Marketa; Grindlay, Guillermo; O'Sullivan, Ciara K; Mora, Juan.
Afiliação
  • Torregrosa D; University of Alicante, Department of Analytical Chemistry, Nutrition and Food Sciences, PO Box 99, 03080, Alicante, Spain.
  • Jauset-Rubio M; INTERFIBIO Consolidated Research Group, Department of Chemical Engineering, Universitat Rovira i Virgili, 43007, Tarragona, Spain.
  • Serrano R; University of Alicante, Department of Analytical Chemistry, Nutrition and Food Sciences, PO Box 99, 03080, Alicante, Spain.
  • Svobodová M; INTERFIBIO Consolidated Research Group, Department of Chemical Engineering, Universitat Rovira i Virgili, 43007, Tarragona, Spain.
  • Grindlay G; University of Alicante, Department of Analytical Chemistry, Nutrition and Food Sciences, PO Box 99, 03080, Alicante, Spain. Electronic address: guillermo.grindlay@ua.es.
  • O'Sullivan CK; INTERFIBIO Consolidated Research Group, Department of Chemical Engineering, Universitat Rovira i Virgili, 43007, Tarragona, Spain; Institució Catalana de Recerca i Estudis Avancats (ICREA), 08010, Barcelona, Spain.
  • Mora J; University of Alicante, Department of Analytical Chemistry, Nutrition and Food Sciences, PO Box 99, 03080, Alicante, Spain.
Anal Chim Acta ; 1252: 341042, 2023 Apr 29.
Article em En | MEDLINE | ID: mdl-36935136
ABSTRACT
The overall objective of this work is the evaluation of different competitive aptamer assays based on inductively coupled plasma mass spectrometry (ICP-MS) detection for the determination of ß-conglutin (food protein allergen from lupin) in flour samples. To this end, two competitive aptamer assay schemes were developed using either thiolated aptamers chemisorbed onto gold nanoparticles (AuNPs) or biotinylated aptamers linked to streptavidin-AuNPs. The influence of ICP-MS detection mode (i.e., conventional vs single particle) on assay performance was explored. In the case of the thiolated aptamer, the limit of detection (LoD) obtained using the single particle mode was improved 2-fold as compared to the LoD provided by the conventional mode. With regards to the biotinylated aptamer, the use of the conventional mode provided a 5-fold improvement of LoD as compared to that obtained for the single particle one. Using the optimized conditions, the best LoD of 2 pM was obtained with the biotinylated aptamer operating with conventional ICP-MS detection. When compared to previous reports using the same aptamer in a competitive assay, the developed method significantly improved the LoD by at least an order of magnitude. Different flour samples containing lupin were successfully analyzed according to European Conformity guidelines for the analysis of food contaminants.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Lupinus / Aptâmeros de Nucleotídeos / Nanopartículas Metálicas Tipo de estudo: Diagnostic_studies Idioma: En Revista: Anal Chim Acta Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Lupinus / Aptâmeros de Nucleotídeos / Nanopartículas Metálicas Tipo de estudo: Diagnostic_studies Idioma: En Revista: Anal Chim Acta Ano de publicação: 2023 Tipo de documento: Article