Your browser doesn't support javascript.
loading
Efficacy and safety of UT-DSAEK combined with Carlevale's sutureless scleral fixation IOL.
Vaiano, Agostino S; Greco, Antonio; Greco, Andrea; Toro, Maria E; Leto, Marco G; Savini, Giacomo.
Afiliação
  • Vaiano AS; Institute of Ophthalmology, Santa Croce e Carle Hospital, Cuneo, Italy.
  • Greco A; Institute of Ophthalmology, Santa Croce e Carle Hospital, Cuneo, Italy.
  • Greco A; Institute of Ophthalmology, Santa Croce e Carle Hospital, Cuneo, Italy.
  • Toro ME; Institute of Ophthalmology, Santa Croce e Carle Hospital, Cuneo, Italy.
  • Leto MG; Institute of Ophthalmology, Santa Croce e Carle Hospital, Cuneo, Italy.
  • Savini G; IRCCS G.B. Bietti Foundation, Rome, Italy.
Eur J Ophthalmol ; 33(6): 2201-2209, 2023 Nov.
Article em En | MEDLINE | ID: mdl-36976933
ABSTRACT

PURPOSE:

To evaluate a novel surgical combination of ultrathin Descemet stripping automated endothelial keratoplasty (UT-DSAEK) and sutureless scleral fixation for Carlevale intraocular lens (SSF-Carlevale IOL) implantation to manage corneal endothelial decompensation when there is a concomitant need for secondary IOL fixation.

METHODS:

Clinical data collected from 10 eyes of 9 patients with bullous keratopathy (BK) who underwent combined UT-DSAEK and SSF-Carlevale IOL implantation in a single procedure were retrospectively analyzed. Anterior chamber IOL (4 cases), aphakia (4 cases, 1 of which associated with PEX), and previous trauma (2 cases) were the conditions responsible for BK. Corrected distance visual acuity (CDVA), intraocular pressure (IOP), endothelial cell density (ECD), central corneal thickness (CCT), graft thickness (GT) and complications were recorded over a 12-month follow-up period.

RESULTS:

In 90% (9/10) of eyes graft clarity was maintained during follow-up. The mean CDVA improved significantly (p < 0.0001) from 1.78 ± 0.76 logMAR preoperatively to 0.53 ± 0.3 logMAR at 12 months. ECD on average decreased from 2575 ± 125.3 cells/mm2 (donor tissue) to 1697 ± 133.3 cells/mm2 in 12 months. The mean CCT decreased from 870 ± 200 µm to 650 µm ± 9 at 12 months (ANOVA, p = 0.0005).

CONCLUSIONS:

Combined UT-DSAEK and SSF-Carlevale IOL implantation was associated with good corneal graft survival and IOP control, with few complications. These findings suggest that this surgical approach is a practical option for patients requiring both treatment for corneal endothelial dysfunction and secondary IOL implantation.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Eur J Ophthalmol Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Eur J Ophthalmol Ano de publicação: 2023 Tipo de documento: Article