Radiographic Outcomes for Comminuted, Intra-articular Distal Radius Fractures Treated with Primary Distraction Bridge Plate Fixation.
Rambau, Genevieve M; Sgromolo, Nicole; Rhee, Peter C.
Afiliação
  • Rambau GM; Department of Orthopaedic Surgery, San Antonio Military Medical Center, 3551 Roger Brooke Drive, San Antonio, TX 78261 USA.
  • Sgromolo N; Department of Orthopaedic Surgery, San Antonio Military Medical Center, 3551 Roger Brooke Drive, San Antonio, TX 78261 USA.
  • Rhee PC; Department of Orthopaedic Surgery, Division of Hand and Microvascular Surgery, Mayo Clinic, 200 First Street SW, Rochester, MN 55905 USA.
Indian J Orthop ; 57(4): 543-551, 2023 Apr.
Article em En | MEDLINE | ID: mdl-37006735
Purpose: To determine if distraction bridge plate (DBP) fixation as the primary method of stabilization can effectively correct and maintain acceptable radiographic parameters in the treatment of comminuted, intra-articular distal radius fractures while allowing early load-bearing. Methods: A retrospective review was performed of all consecutive intra-articular distal radius fractures that underwent DBP fixation with or without supplemental fixation methods (fragment-specific implants or K-wires). Patients treated with a volar locked plate in addition to DBP were excluded. Radiographic outcomes measures included volar tilt (°), radial height (mm), radial inclination (°), articular step-off (mm), lunate-lunate facet ratio (LLFR), and teardrop angle (°) measured on post-reduction, immediately post-operative, prior to and after DBP removal. Results: Twenty-three comminuted, intra-articular distal radius fractures were treated with primary DBP fixation. Supplemental fixation was utilized in 10 fractures and included fragment-specific implants (n = 6) and/or K-wires (n = 5). Distraction bridge plates were removed after a mean of 13.6 weeks. At a mean radiographic follow-up of 11.4 weeks (range: 2-45 weeks) following DBP removal, all fractures had united with a mean volar tilt of 6.3° ± 5.8°, radial height of 11.3 ± 2.3 mm, radial inclination of 20.2° ± 4.5°, articular step-off of 0.6 mm ± 0.8, and LLFR of 1.05 ± 0.06. However, the teardrop angle could not be restored to a normal value with DBP fixation. Complications included 1 plate breakage and 1 peri-hardware radial shaft fracture. Conclusion: Distraction bridge plate fixation is a reliable method to stabilize highly comminuted, intra-articular distal radius fractures in patients with a well-aligned volar rim fragment of the lunate facet.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Indian J Orthop Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Indian J Orthop Ano de publicação: 2023 Tipo de documento: Article