Inter- and Intra-rater Reliability of Modified House-Brackmann and Sunnybrook Facial Nerve Grading Systems in Post Parotidectomy Patients.
Indian J Otolaryngol Head Neck Surg
; 75(1): 100-108, 2023 Mar.
Article
em En
| MEDLINE
| ID: mdl-37007896
To compare inter-rater, intra-rater and inter-system reliability of modified House-Brackmann and Sunnybrook grading systems. The study was conducted in a tertiary care hospital with a single cohort of 20 patients and 3 raters. The patients, eligible to be included for the study, were those over 18 years of age planned for nerve sparing parotidectomy. In the postoperative period, patients were video recorded performing specific movements according to the requirements of modified House-Brackmann and Sunnybrook systems. These recordings were used for the grading once recruitment was completed. The inter-rater, intra-rater and inter-system reliability of modified House-Brackmann and Sunnybrook systems were assessed using the intraclass coefficient. The intra-rater reliability was good-to-excellent for both groups with Intra-Class coefficient (ICC) ranging from 0.902 to 0.958 in modified House-Brackmann and in 0.802 to 0.957 Sunnybrook system. The inter-rater reliability was good-to-excellent with ICC ranging from 0.806 to 0.906 in modified House-Brackmann and 0.766 to 0.860 in Sunnybrook system. The inter-system reliability was good-to-excellent with ICC ranging from 0.892 to 0.937. There was no significant difference in the reliability of modified House-Brackmann and Sunnybrook systems. Thus, an interval scale accomplishes the task of grading facial nerve palsy in a reliable way, and the choice of the specific instrument will be based on other factors like expertise involved, ease of administration and generalisability to the incumbent clinical scenario.
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Idioma:
En
Revista:
Indian J Otolaryngol Head Neck Surg
Ano de publicação:
2023
Tipo de documento:
Article