Your browser doesn't support javascript.
loading
Electrochemical lateral-flow device for rapid COVID-19 antigen-diagnostic testing.
Deenin, Wanwisa; Yakoh, Abdulhadee; Pimpitak, Umaporn; Pasomsub, Ekawat; Rengpipat, Sirirat; Crespo, Gastón A; Chaiyo, Sudkate.
Afiliação
  • Deenin W; Program in Biotechnology, Faculty of Science, Chulalongkorn University, Bangkok, 10330, Thailand; Institute of Biotechnology and Genetic Engineering, Chulalongkorn University, Bangkok, 10330, Thailand.
  • Yakoh A; Institute of Biotechnology and Genetic Engineering, Chulalongkorn University, Bangkok, 10330, Thailand; Center of Excellence for Food and Water Risk Analysis (FAWRA), Department of Veterinary Public Health, Faculty of Veterinary Science, Chulalongkorn University, Bangkok, Thailand.
  • Pimpitak U; Institute of Biotechnology and Genetic Engineering, Chulalongkorn University, Bangkok, 10330, Thailand.
  • Pasomsub E; Department of Pathology, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Bangkok, 10400, Thailand.
  • Rengpipat S; Qualified Diagnostic Development Center (QDD), Chulalongkorn University, Bangkok, 10330, Thailand.
  • Crespo GA; Department of Chemistry, School of Engineering Sciences in Chemistry, Biotechnology and Health, KTH Royal Institute of Technology, Teknikringen 30SE-100 44, Stockholm, Sweden; UCAM SENS, UCAM-SENS, Universidad Católica San Antonio de Murcia, UCAM HiTech, 30107 Murcia, Spain.
  • Chaiyo S; Institute of Biotechnology and Genetic Engineering, Chulalongkorn University, Bangkok, 10330, Thailand; Center of Excellence for Food and Water Risk Analysis (FAWRA), Department of Veterinary Public Health, Faculty of Veterinary Science, Chulalongkorn University, Bangkok, Thailand. Electronic addres
Bioelectrochemistry ; 152: 108438, 2023 Aug.
Article em En | MEDLINE | ID: mdl-37054603
ABSTRACT
Antigen test kits (ATK) are extensively utilized for screening and diagnosing COVID-19 because they are easy to operate. However, ATKs exhibit poor sensitivity and cannot detect low concentrations of SARS-CoV-2. Herein, we present a new, highly sensitive, and selective device obtained by combining the principle of ATKs with electrochemical detection for COVID-19 diagnosis, which can be quantitatively assessed using a smartphone. An electrochemical test strip (E-test strip) was constructed by attaching a screen-printed electrode inside a lateral-flow device to exploit the remarkable binding affinity of SARS-CoV-2 antigen to ACE2. The ferrocene carboxylic acid attached to SARS-CoV-2 antibody acts as an electroactive species when it binds to SARS-CoV-2 antigen in the sample before it flows continuously to the ACE2-immobilization region on the electrode. Electrochemical-assay signal intensity on smartphones increased proportionally to the concentration of SARS-CoV-2 antigen (LOD = 2.98 pg/mL, under 12 min). Additionally, the application of the single-step E-test strip for COVID-19 screening was demonstrated using nasopharyngeal samples, and the results were consistent with those obtained using the gold standard (RT-PCR). Therefore, the sensor demonstrated excellent performance in assessing and screening COVID-19, and it can be used professionally to accurately verify diagnostic data while remaining rapid, simple, and inexpensive.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Teste para COVID-19 / COVID-19 Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: Bioelectrochemistry Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Teste para COVID-19 / COVID-19 Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: Bioelectrochemistry Ano de publicação: 2023 Tipo de documento: Article