Your browser doesn't support javascript.
loading
Sputum handling for rheology.
Esteban Enjuto, Lydia; Robert de Saint Vincent, Matthieu; Maurin, Max; Degano, Bruno; Bodiguel, Hugues.
Afiliação
  • Esteban Enjuto L; Univ. Grenoble Alpes, CNRS, Grenoble-INP, LRP UMR5520, Grenoble, France. estebanl@univ-grenoble-alpes.fr.
  • Robert de Saint Vincent M; Rheonova, 1 Allée de Certèze, 38610, Gières, France. estebanl@univ-grenoble-alpes.fr.
  • Maurin M; Univ. Grenoble Alpes, CNRS, Grenoble-INP, LRP UMR5520, Grenoble, France.
  • Degano B; Rheonova, 1 Allée de Certèze, 38610, Gières, France.
  • Bodiguel H; Univ. Grenoble Alpes, CNRS, CHU Grenoble Alpes, TIMC, Grenoble, France.
Sci Rep ; 13(1): 7695, 2023 05 11.
Article em En | MEDLINE | ID: mdl-37169792
ABSTRACT
The rheology of sputum is viewed as a powerful emerging biophysical marker for monitoring muco-obstructive pulmonary diseases such as cystic fibrosis (CF) and non-CF bronchiectasis (NCFB). However, there is no unified practice to process sputa from collection to analysis, which can lead to highly variable, and sometimes inconsistent results. The main objective of this study is to bring light into the handling of sputum samples to establish a standardised and robust protocol before rheological measurements. Sputum collected from 22 CF and 10 NCFB adults, was divided into control (vortexed and fresh non-heated and non-frozen) and three treated conditions (either non-vortexed, heated or frozen). In addition, 6 CF expectorations were used to study the dynamics of ageing over 24 h. Sputum's mechanical properties were measured with a rotational rheometer to obtain their properties at rest, elastic ([Formula see text]) and viscous moduli ([Formula see text]), and at the onset of flow, critical deformation ([Formula see text]) and critical stress ([Formula see text]). We demonstrate that heating sputum is completely destructive while freezing sputa at [Formula see text] has no discernible effect on their rheology. We also show that the variability of rheological measurements largely resulted from the sample's macroscopic heterogeneity, and can be greatly reduced by non-destructive vortex homogenisation. Finally, we observed contrasted ageing effects as a fonction of purulence while the viscoelasticity of purulent samples reduced by half within 6 h after collection, semi-purulent samples did not evolve. These results guide towards a robust unified protocol for simple sputum handling in rheometry. We therefore suggest to vortex and snap freeze sputum samples immediately after collection when direct testing is not possible.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Bronquiectasia / Fibrose Cística / Pneumopatias Obstrutivas Tipo de estudo: Guideline Limite: Adult / Humans Idioma: En Revista: Sci Rep Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Bronquiectasia / Fibrose Cística / Pneumopatias Obstrutivas Tipo de estudo: Guideline Limite: Adult / Humans Idioma: En Revista: Sci Rep Ano de publicação: 2023 Tipo de documento: Article