Failure to Normalize Biventricular Function Is Associated with Extracorporeal Membrane Oxygenation Use in Neonates with Congenital Diaphragmatic Hernia.
J Pediatr
; 260: 113490, 2023 09.
Article
em En
| MEDLINE
| ID: mdl-37201678
ABSTRACT
We examined postnatal echocardiograms for 62 infants with congenital diaphragmatic hernia born from 2014 through 2020. Left and right ventricular dysfunction on D0 were sensitive, whereas persistent dysfunction on D2 was specific for extracorporeal membrane oxygenation requirement. Biventricular dysfunction had the strongest association with extracorporeal membrane oxygenation. Serial echocardiography may inform prognosis in congenital diaphragmatic hernia.