Your browser doesn't support javascript.
loading
Sex differences in torque steadiness, accuracy and activation of the shoulder girdle muscles during isometric shoulder scaption.
Zancanaro, Lucas Leonardo; Cid, Marina Machado; Côté, Julie N; Oliveira, Ana Beatriz.
Afiliação
  • Zancanaro LL; Laboratory of Clinical and Occupational Kinesiology (LACO), Department of Physical Therapy, Federal University of São Carlos, Rodovia Washington Luís, km 235 - SP-310, São Carlos, São Paulo, Brazil.
  • Cid MM; Laboratory of Clinical and Occupational Kinesiology (LACO), Department of Physical Therapy, Federal University of São Carlos, Rodovia Washington Luís, km 235 - SP-310, São Carlos, São Paulo, Brazil.
  • Côté JN; Department of Kinesiology and Physical Education, McGill University, 475 Pine Avenue West, Montreal, Quebec H2W 1S4, Canada.
  • Oliveira AB; Laboratory of Clinical and Occupational Kinesiology (LACO), Department of Physical Therapy, Federal University of São Carlos, Rodovia Washington Luís, km 235 - SP-310, São Carlos, São Paulo, Brazil. Electronic address: biaoliveira@ufscar.br.
J Biomech ; 155: 111638, 2023 06.
Article em En | MEDLINE | ID: mdl-37216896
ABSTRACT
Females present more neck/shoulder musculoskeletal disorders and have different activation strategies of the shoulder girdle muscles than males. However, the sensorimotor performance and potential sex differences are still largely unexplored. The aim of this study was to investigate sex differences in torque steadiness and accuracy during isometric shoulder scaption. We also examined the amplitude and variability of the activation of the trapezius, serratus anterior (SA), and anterior deltoid muscles during torque output evaluation. Thirty-four asymptomatic adults (17 females) participated. Torque steadiness and accuracy were evaluated during submaximal contractions at 20 % and 35 % of peak torque (PT). There was no sex difference in torque coefficient of variation, but females had significantly lower torque standard deviation (SD) values than males at the two intensities evaluated (p < 0.001) and lower torque median frequency values compared to males, regardless of intensity (p < 0.01). Females had significantly lower absolute error values than males for torque output at 35 %PT (p < 0.01) and lower constant error values compared to males, regardless of intensity (p = 0.01). Females had significantly higher muscle amplitude values than males, except for SA (p = 0.10) and in general, females showed higher muscle activation SD values compared to males (p < 0.05). Females may require more complex muscle activation patterns to achieve a more stable and accurate torque output. Therefore, these sex differences may reflect control mechanisms that may also be at play when explaining the greater risk of neck/shoulder musculoskeletal disorders in females than males.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Articulação do Ombro / Doenças Musculoesqueléticas / Músculos Superficiais do Dorso Limite: Adult / Female / Humans / Male Idioma: En Revista: J Biomech Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Articulação do Ombro / Doenças Musculoesqueléticas / Músculos Superficiais do Dorso Limite: Adult / Female / Humans / Male Idioma: En Revista: J Biomech Ano de publicação: 2023 Tipo de documento: Article