Your browser doesn't support javascript.
loading
Three-Dimensional Evaluation of Skeletal Stability following Surgery-First Orthognathic Approach: Validation of a Simple and Effective Method.
Mansour, Nabil M; Abdelshaheed, Mohamed E; El-Sabbagh, Ahmed H; El-Din, Ahmed M Bahaa; Kim, Young Chul; Choi, Jong-Woo.
Afiliação
  • Mansour NM; Faculty of Medicine, Department of Plastic and Reconstructive Surgery, Mansoura University, Mansoura, Egypt.
  • Abdelshaheed ME; Faculty of Medicine, Department of Plastic and Reconstructive Surgery, Mansoura University, Mansoura, Egypt.
  • El-Sabbagh AH; Faculty of Medicine, Department of Plastic and Reconstructive Surgery, Mansoura University, Mansoura, Egypt.
  • El-Din AMB; Faculty of Medicine, Department of Plastic and Reconstructive Surgery, Mansoura University, Mansoura, Egypt.
  • Kim YC; Department of Plastic and Reconstructive Surgery, Ulsan University College of Medicine, Seoul Asan Medical Center, Seoul, South Korea.
  • Choi JW; Department of Plastic and Reconstructive Surgery, Ulsan University College of Medicine, Seoul Asan Medical Center, Seoul, South Korea.
Arch Plast Surg ; 50(3): 254-263, 2023 May.
Article em En | MEDLINE | ID: mdl-37256039
ABSTRACT
Background The three-dimensional (3D) evaluation of skeletal stability after orthognathic surgery is a time-consuming and complex procedure. The complexity increases further when evaluating the surgery-first orthognathic approach (SFOA). Herein, we propose and validate a simple time-saving method of 3D analysis using a single software, demonstrating high accuracy and repeatability. Methods This retrospective cohort study included 12 patients with skeletal class 3 malocclusion who underwent bimaxillary surgery without any presurgical orthodontics. Computed tomography (CT)/cone-beam CT images of each patient were obtained at three different time points (preoperation [T0], immediately postoperation [T1], and 1 year after surgery [T2]) and reconstructed into 3D images. After automatic surface-based alignment of the three models based on the anterior cranial base, five easily located anatomical landmarks were defined to each model. A set of angular and linear measurements were automatically calculated and used to define the amount of movement (T1-T0) and the amount of relapse (T2-T1). To evaluate the reproducibility, two independent observers processed all the cases, One of them repeated the steps after 2 weeks to assess intraobserver variability. Intraclass correlation coefficients (ICCs) were calculated at a 95% confidence interval. Time required for evaluating each case was recorded. Results Both the intra- and interobserver variability showed high ICC values (more than 0.95) with low measurement variations (mean linear variations 0.18 mm; mean angular variations 0.25 degree). Time needed for the evaluation process ranged from 3 to 5 minutes. Conclusion This approach is time-saving, semiautomatic, and easy to learn and can be used to effectively evaluate stability after SFOA.