Your browser doesn't support javascript.
loading
Rotary Bend Fatigue of Nitinol to One Billion Cycles.
Weaver, J D; Sena, G M; Aycock, K I; Roiko, A; Falk, W M; Sivan, S; Berg, B T.
Afiliação
  • Weaver JD; U.S. Food and Drug Administration (FDA), Silver Spring, MD, USA.
  • Sena GM; U.S. Food and Drug Administration (FDA), Silver Spring, MD, USA.
  • Aycock KI; U.S. Food and Drug Administration (FDA), Silver Spring, MD, USA.
  • Roiko A; Medtronic, Mounds View, MN, USA.
  • Falk WM; Medtronic, Mounds View, MN, USA.
  • Sivan S; U.S. Food and Drug Administration (FDA), Silver Spring, MD, USA.
  • Berg BT; Boston Scientific (BSC), Maple Grove, MN, USA.
Shap Mem Superelasticity ; 9: 50-73, 2023 Jan 18.
Article em En | MEDLINE | ID: mdl-37261068
ABSTRACT
Nitinol implants, especially those used in cardiovascular applications, are typically expected to remain durable beyond 108 cycles, yet literature on ultra-high cycle fatigue of nitinol remains relatively scarce and its mechanisms not well understood. To investigate nitinol fatigue behavior in this domain, we conducted a multifaceted evaluation of nitinol wire subjected to rotary bend fatigue that included detailed material characterization and finite element analysis as well as post hoc analyses of the resulting fatigue life data. Below approximately 105 cycles, cyclic phase transformation, as predicted by computational simulations, was associated with fatigue failure. Between 105 and 108 cycles, fractures were relatively infrequent. Beyond 108 cycles, fatigue fractures were relatively common depending on the load level and other factors including the size of non-metallic inclusions present and the number of loading cycles. Given observations of both low cycle and ultra-high cycle fatigue fractures, a two-failure model may be more appropriate than the standard Coffin-Manson equation for characterizing nitinol fatigue life beyond 108 cycles. This work provides the first documented fatigue study of medical grade nitinol to 109 cycles, and the observations and insights described will be of value as design engineers seek to improve durability for future nitinol implants.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Revista: Shap Mem Superelasticity Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Revista: Shap Mem Superelasticity Ano de publicação: 2023 Tipo de documento: Article