Your browser doesn't support javascript.
loading
In vitro research of oral microscope-assisted implant surface decontamination.
Su, Wenqi; Li, Jingwen; Jiang, Lishan; Cui, Wenjie; Zhao, Yang; Li, Houxuan.
Afiliação
  • Su W; Dept. of Periodontics, Nanjing Stomatological Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing 210008, China.
  • Li J; Dept. of Periodontics, Nanjing Stomatological Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing 210008, China.
  • Jiang L; Dept. of Periodontics, Nanjing Stomatological Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing 210008, China.
  • Cui W; Dept. of Periodontics, Nanjing Stomatological Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing 210008, China.
  • Zhao Y; Dept. of Periodontics, Nanjing Stomatological Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing 210008, China.
  • Li H; Dept. of Periodontics, Nanjing Stomatological Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing 210008, China.
Hua Xi Kou Qiang Yi Xue Za Zhi ; 41(3): 350-355, 2023 Jun 01.
Article em En, Zh | MEDLINE | ID: mdl-37277802
ABSTRACT

OBJECTIVES:

To investigate the effect of oral microscope-assisted surface decontamination on implants in vitro.

METHODS:

Twelve implants that fell off because of severe peri-implantitis were collected, and decontamination was carried out on the surfaces of implants through curetting, ultrasound, titanium brushing, and sandblasting at 1×, 8×, or 12.8× magnifications. The number and sizes of residues on the implants' surfaces after decontamination were determined, and the decontamination effect was analyzed according to the thread spacing in the different parts of the thread.

RESULTS:

1) The 8× and 12.8× groups scored lower for implant surface residues than the 1× group (P<0.000 1), and the 12.8× group scored lower than the 8× group (P<0.001); 2) no difference in residue score was found between the wide and narrow thread pitch (P>0.05), and the 8× and 12.8× groups had lower scores than the 1× group (P<0.001); 3) the lowest number of contaminants was observed at the tip of the thread, whereas the highest was observed below the thread, and the difference was significant (P<0.001). However, the thread pitch had no effect on the number of contaminants in different areas (P>0.05); 4) the residue scores of the 8× and 12.8× groups were lower than those of the 1× group at the thread tip and above, sag, and below the thread of the implants (P<0.05).

CONCLUSIONS:

Residues on the surfaces of contaminated implants can be effectively removed by using an oral microscope. After decontamination, the residues of pollutants were mainly concentrated below the thread of the implants, and the thread pitch of the implants had no significant effect on the residues.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Implantes Dentários / Peri-Implantite Limite: Humans Idioma: En / Zh Revista: Hua Xi Kou Qiang Yi Xue Za Zhi Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Implantes Dentários / Peri-Implantite Limite: Humans Idioma: En / Zh Revista: Hua Xi Kou Qiang Yi Xue Za Zhi Ano de publicação: 2023 Tipo de documento: Article