Your browser doesn't support javascript.
loading
Assessment of Three Breast Volume Measurement Techniques: Single Marking, MRI and Crisalix 3D Software®.
Markovic, Aleksandra; Pessoa, Salustiano Gomes de Pinho; Leite, José Alberto Dias; de Alcântara, Fernando Soares; Collaço, Bernardo Gabriele; Ariel de Lima, Diego.
Afiliação
  • Markovic A; Department of Surgery, UFC - Universidade Federal do Ceará, Fortaleza, CE, Brazil.
  • Pessoa SGP; Department of Surgery, UFC - Universidade Federal do Ceará, Fortaleza, CE, Brazil.
  • Leite JAD; Department of Surgery, UFC - Universidade Federal do Ceará, Fortaleza, CE, Brazil.
  • de Alcântara FS; Department of Surgery, UFC - Universidade Federal do Ceará, Fortaleza, CE, Brazil.
  • Collaço BG; Department of Surgery, UFC - Universidade Federal do Ceará, Fortaleza, CE, Brazil.
  • Ariel de Lima D; Department of Health Sciences, UFERSA - Universidade Federal Rural do Semi-Árido, Rua Francisco Mota, 572, Pres. Costa e Silva, Mossoró, RN, 57259625-900, Brazil. arieldelima.diego@gmail.com.
Aesthetic Plast Surg ; 47(5): 1751-1758, 2023 10.
Article em En | MEDLINE | ID: mdl-37337054
ABSTRACT

INTRODUCTION:

Measuring breast volume is important to obtain satisfactory breast surgery results, and many techniques are used for this purpose. Thus, the aim of the present study was to compare 3 breast volume techniques Pessoa's single marking technique, magnetic resonance imaging (MRI) and Crisalix 3D software®.

METHODS:

Fourteen patients indicated for mammoplasty were selected. Three breast volume measurement techniques were compared Pessoa's single marking technique, MRI and Crisalix 3D software®. The volumes were tabulated and analyzed using R software.

RESULTS:

Average age was 30.93 ± 10.25 years. The breast volume was 1554.54 ± 512.54 cm3, as measured by the MRI technique (considered the gold standard), 1199.64 ± 403.13 cm3 using Crisalix 3D software® and 1518.04 ± 468.72 cm3 by Pessoa's single marking technique. Comparison between the Crisalix 3D software® and MRI techniques using the pairwise t test demonstrated a statistically significant difference (t = 4.3957, df = 27, p value = 0001543), but no significant difference between the single marking and MRI techniques (t = 1.3841, df = 27, p value = 0.1777).

CONCLUSION:

When compared to MRI, breast volume measurement using Pessoa's single marking technique showed no statistically significant difference between them. However, the Crisalix 3D® technique exhibited a difference in relation to MRI. Anthropometric measurements are useful in measuring breast volume because they are easy to obtain, practical and inexpensive, and should be part of a plastic surgeon's arsenal. LEVEL OF EVIDENCE IV This journal requires that authors assign a level of evidence to each article. For a full description of these evidence-based medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .