Ti3C2Tx MXene -facilitated non-selective trapping effect: Efficient SERS detection of exosomal PD-L1.
Zhou, Yangyang; Chen, Qiang; Zhong, Suyun; Liu, Hezhen; Koh, Kwangnak; Chen, Hongxia.
Afiliação
  • Zhou Y; School of Medicine, Shanghai University, Shanghai, 200444, PR China; School of Environmental and Chemical Engineering, Shanghai University, Shanghai, 200444, PR China.
  • Chen Q; School of Medicine, Shanghai University, Shanghai, 200444, PR China.
  • Zhong S; School of Life Sciences, Shanghai University, Shanghai, 200444, PR China.
  • Liu H; School of Life Sciences, Shanghai University, Shanghai, 200444, PR China.
  • Koh K; Institute of General Education, Pusan National University, Busan, 609-735, Republic of Korea.
  • Chen H; School of Life Sciences, Shanghai University, Shanghai, 200444, PR China. Electronic address: hxchen@shu.edu.cn.
Biosens Bioelectron ; 237: 115493, 2023 Oct 01.
Article em En | MEDLINE | ID: mdl-37364303
Biosensors developed through a sandwich approach have demonstrated favorable detection performance for exosomal programmed cell death 1 ligand 1 (ExoPD-L1) detection. However, the reported PD-L1 antibodies, peptides, and aptamers utilized in these biosensors typically bind to the extracellular region, with overlapping binding sites that severely constrain the fabrication of biosensors. In this study, we present a simple approach to specifically identify and analyze ExoPD-L1 through the non-selective trapping effect of Ti3C2TX (X=-O, -F, -OH) MXene on exosomes via the formation of Ti-O-P complexation, and the selective capture of peptide-functionalized Au@MPBA (4-Mercaptophenylboronic acid) @SiO2 surface enhanced Raman scattering (SERS) tags on ExoPD-L1. The biosensor delivered a both hypersensitive and reliable performance in exosome detection with a low limit of detection (20.74 particles/mL) in the linear range of 102 to 5×106 particles/mL. Furthermore, the biosensor demonstrated excellent stability and interference resistance in detecting ExoPD-L1 in clinical serum samples, enabling the easy differentiation of breast cancer patients from healthy controls. This work provides new insights into the design of biosensors for exosome detection and can serve as a replicable template for sandwich immunoassay detection for other types of sensors, including but not limited to SERS.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: Biosens Bioelectron Ano de publicação: 2023 Tipo de documento: Article