Your browser doesn't support javascript.
loading
Short-term changes detected by corneal topography and optical coherence tomography after prophylactic laser iridotomy in primary angle closure suspect.
Sahin, Ömer Faruk; Degirmenci, Mehmet Fatih Kagan; Bahar, Alperen; Isik, Mehmed Ugur.
Afiliação
  • Sahin ÖF; Ophthalmology Clinic, Etimesgut State Hospital, Ankara, Turkey.
  • Degirmenci MFK; Department of Ophthalmology, Lokman Hekim University Ankara Hospital, Ankara, Turkey. mfkdegirmenci@ankara.edu.tr.
  • Bahar A; Department of Ophthalmology, Diskapi Training and Research Hospital, Ankara, Turkey.
  • Isik MU; Department of Ophthalmology, Kastamonu Training and Research Hospital, Kastamonu, Turkey.
Int Ophthalmol ; 43(10): 3803-3809, 2023 Oct.
Article em En | MEDLINE | ID: mdl-37410298
ABSTRACT

PURPOSE:

To evaluate early changes in anterior segment parameters by Scheimpflug-Placido disc topography system and changes in retinal layers by optical coherence tomography in primary angle-closure suspects after laser peripheral iridotomy.

METHODS:

One eye of 26 patients with primary angle closure suspect and of 20 healthy subjects were included in this retrospective cross-sectional study. Anterior chamber depth/volume, iridocorneal angle and central corneal thickness were obtained by Scheimpflug-Placido disc topography system. Retinal thickness, retinal nerve fiber layer thickness and ganglion cell-inner plexiform layer thickness were acquired by optical coherence tomography. All the tests were repeated 1 week and 1 month after laser peripheral iridotomy.

RESULTS:

The mean ages of the patients and healthy controls were 64.8 ± 10.7 years and 64.5 ± 3.9 years, respectively (p = 0.990). Anterior chamber depth/volume and iridocorneal angle value were lower in the PACS group (p < 0.001, for all). Anterior chamber volume and iridocorneal angle increased significantly after laser peripheral iridotomy (p = 0.004, for both). While foveal thickness decreased significantly after laser peripheral iridotomy (p = 0.027), retinal nerve fiber layer thickness increased in superior and temporal quadrants (p = 0.038 and p = 0.016, respectively).

CONCLUSION:

Our results suggest that LPI in patients with PACS provides improved retinal thickness and RNFL thickness, as well as anterior chamber parameters.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Glaucoma de Ângulo Fechado / Terapia a Laser Tipo de estudo: Diagnostic_studies / Observational_studies / Prevalence_studies / Risk_factors_studies Limite: Aged / Humans / Middle aged Idioma: En Revista: Int Ophthalmol Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Glaucoma de Ângulo Fechado / Terapia a Laser Tipo de estudo: Diagnostic_studies / Observational_studies / Prevalence_studies / Risk_factors_studies Limite: Aged / Humans / Middle aged Idioma: En Revista: Int Ophthalmol Ano de publicação: 2023 Tipo de documento: Article