Your browser doesn't support javascript.
loading
Development and validation of simultaneous quantification method for gemcitabine and betulinic acid: augmenting industrial application.
Tiwari, A K; Yadav, P K; Saklani, R; Rana, R; Alam, M N; Chourasia, M K.
Afiliação
  • Tiwari AK; Division of Pharmaceutics and Pharmacokinetics, CSIR-Central Drug Research Institute, Lucknow, UP 226031 India.
  • Yadav PK; Academy of Scientific and Innovative Research (AcSIR), Ghaziabad, Uttar Pradesh 201002 India.
  • Saklani R; Division of Pharmaceutics and Pharmacokinetics, CSIR-Central Drug Research Institute, Lucknow, UP 226031 India.
  • Rana R; Academy of Scientific and Innovative Research (AcSIR), Ghaziabad, Uttar Pradesh 201002 India.
  • Alam MN; Division of Pharmaceutics and Pharmacokinetics, CSIR-Central Drug Research Institute, Lucknow, UP 226031 India.
  • Chourasia MK; Academy of Scientific and Innovative Research (AcSIR), Ghaziabad, Uttar Pradesh 201002 India.
3 Biotech ; 13(8): 267, 2023 Aug.
Article em En | MEDLINE | ID: mdl-37431395
ABSTRACT
Combinatorial treatment utilizing a nucleoside analogue gemcitabine (GEM), with a characteristic pentacyclic triterpenoid betulinic acid (BET), has exhibited empowering adequacy in the therapy of cancer. It lessens the advancement of collagen and upgrades the saturation of tumour medicines. With the advancement in nanotechnology, the co-loaded formulation urges for a validated method of estimation. The purposed work entails a robust, simple, and economical analytical method for the simultaneous estimation of GEM and BET through RP-HPLC. Orthophosphoric acid (0.1%)-acetonitrile was considered as the mobile phase for the detection of GEM and BET at 248 nm and 210 nm with retention times of 5 min and 13 min, respectively. The method was further validated as per the regulatory guidelines with all the parameters found within the limit. The developed method with adequate resolution and quantification was found to be linear, accurate, precise, robust, and stable with an intra- and inter-day variability of less than 2%. The method was found specific for GEM and BET with no matrix interference of drug-spiked FBS samples. To demonstrate the applicability of the developed method, a nano-formulation containing GEM and BET was prepared and assessed for various parameters including encapsulation efficiency, loading efficiency, drug release, and drug stability. The method developed can be a possible tool for the simultaneous quantification of GEM-BET in analytical and biological samples.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Guideline Idioma: En Revista: 3 Biotech Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Guideline Idioma: En Revista: 3 Biotech Ano de publicação: 2023 Tipo de documento: Article