Your browser doesn't support javascript.
loading
SPECT and PET myocardial perfusion imaging in Austria, Germany, and Switzerland results of the first joint survey of 2021.
Lindner, O; Hacker, M; Burchert, W; Buechel, R R.
Afiliação
  • Lindner O; Institut für Radiologie, Nuklearmedizin und Molekulare Bildgebung, Herz- und Diabeteszentrum NRW, Georgstr. 11, Bad Oeynhausen, Germany. olindner@hdz-nrw.de.
  • Hacker M; Klinische Abteilung für Nuklearmedizin, Universitätsklinik für Radiologie und Nuklearmedizin, Medizinische Universität Wien, Vienna, Austria.
  • Burchert W; Institut für Radiologie, Nuklearmedizin und Molekulare Bildgebung, Herz- und Diabeteszentrum NRW, Georgstr. 11, Bad Oeynhausen, Germany.
  • Buechel RR; Klinik für Nuklearmedizin, Universitätsspital Zürich, Zurich, Switzerland.
Eur J Nucl Med Mol Imaging ; 50(12): 3602-3608, 2023 10.
Article em En | MEDLINE | ID: mdl-37452873
ABSTRACT

PURPOSE:

This paper presents the results of the first joint survey on the use of SPECT and PET myocardial perfusion imaging (MPI) and cardiac amyloidosis imaging in Austria, Germany, and Switzerland of the year 2021.

METHODS:

A questionnaire was sent in 2022 to centres practicing nuclear medicine.

RESULTS:

Data from 14 Austrian (10,710 SPECT), 218 German (133,047 SPECT), and 16 Swiss centres (11,601 MPI (6,879 SPECT, 4722 PET)) were analysed. In Austria and Germany, the PET MPI numbers were close to zero and not considered. Official MPS numbers from 2015 to 2021 from Austria and Germany revealed a decline in Austria by about 40% in the pandemic years 2020 to 2021, but an increase in Germany by 9%. Ambulatory care cardiologists represented the major referral group (56-71%). Mostly, stress tests were performed pharmacologically (58-92%). Contrary to Germany, a 1-day protocol was predominant (58-97%) in Austria and Switzerland. The leading camera systems were SPECT-CT in Austria and Switzerland (57-79%) and multi-head systems in Germany (58%). Switzerland had the highest proportion of SPECT MPI with attenuation correction (84%), followed by Austria (43%), and Germany (33%). Electrocardiogram-gated SPECT MPI showed an overall high penetration of 87-99%. Scoring was most frequently applied in Germany (72%), followed by Austria (64%), and Switzerland (60%). Related to the population, the number of cardiac amyloidosis imaging was highest in Austria, followed by Switzerland and Germany.

CONCLUSIONS:

This first joint survey of 2021 shows considerable differences among the countries. The Swiss situation is outstanding due to the wide use of PET MPI. In terms of camera equipment, Switzerland is also leading, followed by Austria and Germany. Despite the differences in procedural issues, the results reveal an overall high standard of MPI imaging.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imagem de Perfusão do Miocárdio Limite: Humans País/Região como assunto: Europa Idioma: En Revista: Eur J Nucl Med Mol Imaging Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imagem de Perfusão do Miocárdio Limite: Humans País/Região como assunto: Europa Idioma: En Revista: Eur J Nucl Med Mol Imaging Ano de publicação: 2023 Tipo de documento: Article