Your browser doesn't support javascript.
loading
Ultra-High-Performance Liquid Chromatography Quadrupole Time-of-Flight Mass Spectrometry for Simultaneous Pesticide Analysis and Method Validation in Sweet Pepper.
Bang, Han Yeol; Kim, Yong-Kyoung; Kim, Hyoyoung; Baek, Eun Joo; Na, Taewoong; Sim, Kyu Sang; Kim, Ho Jin.
Afiliação
  • Bang HY; Gyeongnam Provincial Office, National Agricultural Products Quality Management Service, Busan 47537, Republic of Korea.
  • Kim YK; Experiment Research Institute, National Agricultural Products Quality Management Service, Gimcheon-si 39660, Republic of Korea.
  • Kim H; Experiment Research Institute, National Agricultural Products Quality Management Service, Gimcheon-si 39660, Republic of Korea.
  • Baek EJ; Experiment Research Institute, National Agricultural Products Quality Management Service, Gimcheon-si 39660, Republic of Korea.
  • Na T; Experiment Research Institute, National Agricultural Products Quality Management Service, Gimcheon-si 39660, Republic of Korea.
  • Sim KS; Experiment Research Institute, National Agricultural Products Quality Management Service, Gimcheon-si 39660, Republic of Korea.
  • Kim HJ; Experiment Research Institute, National Agricultural Products Quality Management Service, Gimcheon-si 39660, Republic of Korea.
Molecules ; 28(14)2023 Jul 22.
Article em En | MEDLINE | ID: mdl-37513461
Pesticides effectively reduce the population of various pests that harm crops and increase productivity, but leave residues that adversely affect health and the environment. Here, a simultaneous multicomponent analysis method based on ultra-high-performance liquid chromatography quadrupole time-of-flight mass spectrometry (UHPLC-QTOF-MS) pretreated by the QuEChERS method was developed to control the maximum residual levels. Among the 140 pesticides with high frequency of detection in agricultural products in Gyeongnam region in Korea for 5 years, 12 pesticides with high detection frequency in sweet pepper were selected. The analytical method is validated, linearities are r2 > 0.999, limit of detection (LOD) ranges from 1.4 to 3.2 µg/kg, and limit of quantification (LOQ) ranges from 4.1 to 9.7 µg/kg, and the recovery rate was 81.7-99.7%. In addition, it was confirmed that a meaningful value of these parameters can be achieved by determining the measurement uncertainty. The results proved that parameters such as recovery rate and relative standard deviation of the analysis method were within international standards. Using the developed method, better and safer sweet peppers will be provided to consumers, and effective pesticide residue management will be possible by expanding to other agricultural products.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Praguicidas / Capsicum / Resíduos de Praguicidas Idioma: En Revista: Molecules Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Praguicidas / Capsicum / Resíduos de Praguicidas Idioma: En Revista: Molecules Ano de publicação: 2023 Tipo de documento: Article