Your browser doesn't support javascript.
loading
All-inorganic Mn2+-doped metal halide perovskite crystals for the late-time detection of X-ray afterglow imaging.
Wu, Sijian; Yuan, Lifang; Chen, Geng; Peng, Chaoyue; Jin, Yahong.
Afiliação
  • Wu S; School of Physics and Optoelectronic Engineering, Guangdong University of Technology, WaiHuan Xi Road, No. 100, Guangzhou 510006, PR China. yhjin@gdut.edu.cn.
  • Yuan L; School of Electronics and Communications, Guangdong Mechanical & Electrical Polytechnic, Guangzhou 510515, PR China.
  • Chen G; School of Physics and Optoelectronic Engineering, Guangdong University of Technology, WaiHuan Xi Road, No. 100, Guangzhou 510006, PR China. yhjin@gdut.edu.cn.
  • Peng C; School of Physics and Optoelectronic Engineering, Guangdong University of Technology, WaiHuan Xi Road, No. 100, Guangzhou 510006, PR China. yhjin@gdut.edu.cn.
  • Jin Y; School of Physics and Optoelectronic Engineering, Guangdong University of Technology, WaiHuan Xi Road, No. 100, Guangzhou 510006, PR China. yhjin@gdut.edu.cn.
Nanoscale ; 15(33): 13628-13634, 2023 Aug 25.
Article em En | MEDLINE | ID: mdl-37526988
ABSTRACT
All-inorganic metal halide perovskite (MHP) materials have been widely studied because of their unique optoelectronic properties, whereas there has been little research reported on their X-ray afterglow imaging properties. Herein, we report the design and synthesis of Mn2+-doped hexagonal CsCdCl3 MHP crystals with excellent X-ray scintillation and X-ray induced afterglow. The orange emission from Mn2+ shows a red shift due to the strong interaction of the Mn2+-Mn2+ dimers formed at higher doping concentrations. The high-energy X-rays with higher electron filling capacity to feed the shallow (0.71 eV) and deep (0.90-1.08 eV) traps enable a long orange afterglow for more than 300 min. The afterglow emission can be rejuvenated effectively by 870 nm stimulus or heating even after 72 h of decay. Finally, we demonstrate the proof-of-concept applications of the fabricated flexible scintillator films for real-time online X-ray imaging with a spatial resolution of 12.2 lp mm-1, as well as time-lapse X-ray imaging recorded by a cell phone, which shows promise for being able to do offline late-time detection of X-ray afterglow imaging in the future.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: Nanoscale Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: Nanoscale Ano de publicação: 2023 Tipo de documento: Article