Your browser doesn't support javascript.
loading
Automated microextraction by packed sorbent of endocrine disruptors in wastewater using a high-throughput robotic platform followed by liquid chromatography-tandem mass spectrometry.
Bocelli, Marcio David; Medina, Deyber Arley Vargas; Lanças, Fernando Mauro; Dos Santos-Neto, Álvaro José.
Afiliação
  • Bocelli MD; São Carlos Institute of Chemistry, University of São Paulo, São Carlos, SP, Brazil.
  • Medina DAV; São Carlos Institute of Chemistry, University of São Paulo, São Carlos, SP, Brazil.
  • Lanças FM; São Carlos Institute of Chemistry, University of São Paulo, São Carlos, SP, Brazil.
  • Dos Santos-Neto ÁJ; São Carlos Institute of Chemistry, University of São Paulo, São Carlos, SP, Brazil. alvarojsn@iqsc.usp.br.
Anal Bioanal Chem ; 415(25): 6165-6176, 2023 Oct.
Article em En | MEDLINE | ID: mdl-37532864
An automated microextraction by packed sorbent followed by liquid chromatography-tandem mass spectrometry (MEPS-LC-MS/MS) method was developed for the determination of four endocrine disruptors-parabens, benzophenones, and synthetic phenolic antioxidants-in wastewater samples. The method utilizes a lab-made repackable MEPS device and a multi-syringe robotic platform that provides flexibility to test small quantities (2 mg) of multiple extraction phases and enables high-throughput capabilities for efficient method development. The overall performance of the MEPS procedure, including the investigation of influencing variables and the optimization of operational parameters for the robotic platform, was comprehensively studied through univariate and multivariate experiments. Under optimized conditions, the target analytes were effectively extracted from a small sample volume of 1.5 mL, with competitive detectability and analytical confidence. The limits of detection ranged from 0.15 to 0.30 ng L-1, and the intra-day and inter-day relative standard deviations were between 3 and 21%. The method's applicability was successfully demonstrated by determining methylparaben, propylparaben, butylated hydroxyanisole, and oxybenzone in wastewater samples collected from the São Carlos (SP, Brazil) river. Overall, the developed method proved to be a fast, sensitive, reliable, and environmentally friendly analytical tool for water quality monitoring.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Anal Bioanal Chem Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Anal Bioanal Chem Ano de publicação: 2023 Tipo de documento: Article