Your browser doesn't support javascript.
loading
Cinnamyl Chalcone Based AIE Fluorescent Probes for Sensitive Detection of Hydrazine and its Application in Living Cells.
Yang, Yun-Shang; Yuan, Yi-Zhen; Zhang, Ying-Peng; Guo, Hui-Chen; Xue, Ji-Jun.
Afiliação
  • Yang YS; School of Petrochemical Engineering & Key Laboratory of Low Carbon Energy and Chemical Engineering of Gansu, Lanzhou University of Technology, Lanzhou, 730050, China. yangyunshang@tom.com.
  • Yuan YZ; School of Petrochemical Engineering & Key Laboratory of Low Carbon Energy and Chemical Engineering of Gansu, Lanzhou University of Technology, Lanzhou, 730050, China.
  • Zhang YP; School of Petrochemical Engineering & Key Laboratory of Low Carbon Energy and Chemical Engineering of Gansu, Lanzhou University of Technology, Lanzhou, 730050, China. yingpengzhang@126.com.
  • Guo HC; State Key Laboratory of Veterinary Etiological Biology and Key Laboratory of Animal Virology of Ministry of Agriculture, Lanzhou Veterinary Research Institute, Chinese Academy of Agricultural Sciences, Lanzhou, 730046, China.
  • Xue JJ; State Key Laboratory of Applied Organic Chemistry & College of Chemistry and Chemical Engineering, Lanzhou University, Lanzhou, 730000, China.
J Fluoresc ; 2023 Aug 10.
Article em En | MEDLINE | ID: mdl-37561367
Widely utilized in the chemical industry and agriculture, hydrazine is easily absorbed by living things and can cause physical harm when in touch for an extended period of time. As a result, a novel cinnamaldehyde chalcone C5 was produced by Friedel Crafts process and aldol condensation reaction. Triphenylamine was used as the raw material for hydrazine determination in both reactions. Chalcone C5 exhibits significant AIE behavior in a mixed mixture of ethanol and water in addition to having great selectivity and a low detection limit (0.119 nm) for hydrazine. The solvent effect test revealed a linear relationship between the Stokes shift of C5 in the solvent and the rise in solvent orientation polarization. It is important to note that C5 is not harmful to MCF-7 cells, mouse kidney cells, or pig kidney cells. Furthermore, research on cell imaging has demonstrated that probe C5 may be utilized to image the fluorescence of hydrazine in active MCF-7 cells.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: J Fluoresc Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: J Fluoresc Ano de publicação: 2023 Tipo de documento: Article