Your browser doesn't support javascript.
loading
Hydrogel-enzyme micropatch array format for chemical mapping: A proof of concept.
Huang, Li-Li; Chua, Zi Qing; Buchowiecki, Krzysztof; Raju, Chamarthi Maheswar; Urban, Pawel L.
Afiliação
  • Huang LL; Department of Chemistry, National Tsing Hua University, 101, Section 2, Kuang-Fu Rd., Hsinchu, 300044, Taiwan.
  • Chua ZQ; Department of Chemistry, National Tsing Hua University, 101, Section 2, Kuang-Fu Rd., Hsinchu, 300044, Taiwan.
  • Buchowiecki K; Department of Chemistry, National Tsing Hua University, 101, Section 2, Kuang-Fu Rd., Hsinchu, 300044, Taiwan.
  • Raju CM; Department of Chemistry, National Tsing Hua University, 101, Section 2, Kuang-Fu Rd., Hsinchu, 300044, Taiwan.
  • Urban PL; Department of Chemistry, National Tsing Hua University, 101, Section 2, Kuang-Fu Rd., Hsinchu, 300044, Taiwan; Frontier Research Center on Fundamental and Applied Sciences of Matters, National Tsing Hua University, 101, Section 2, Kuang-Fu Rd., Hsinchu, 300044, Taiwan. Electronic address: urban@mx.n
Biosens Bioelectron ; 239: 115599, 2023 Nov 01.
Article em En | MEDLINE | ID: mdl-37611447
Conventional sensing methods report on concentrations of analytes in a single point of sampled medium or provide an average value. However, distributions of substances on surfaces of sampled objects often exhibit intricate inhomogeneities. In order to obtain snapshots of the chemical distributions on surfaces, we have developed enzyme-loaded hydrogel arrays (5 × 5 and 10 × 10). The acrylic 10 × 10 array base contains 100 holes, which are filled with agarose hydrogel containing assay enzymes and substrates. Such arrays can be exposed to the analyzed surfaces to collect minute amounts of analytes. Following a brief incubation, they are subsequently visualized in a custom-built array reader device. The reader incorporates a light-emitting diode-based light source, miniature camera, and Raspberry Pi single-board computer. Two Python programs capture and analyze the images of the array to extract pixel saturation values corresponding to individual hydrogel micropatches. The method has been thoroughly optimized for mapping of glucose and lactic acid. The optimized parameters were: contact time, agarose concentration, substrate concentration, enzyme concentration ratio, and enzyme concentration. The array biosensor was further tested by mapping glucose distribution in fruit/vegetable cross-sections (apple, guava, and cucumber) and lactic acid distribution in cheese. We think that this new hydrogel-based chemical mapping method can find applications in studies related to food science, plant physiology, clinical chemistry, and forensics; wherever the distributions of analytes on the tested surfaces need to be assessed.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Hidrogéis Idioma: En Revista: Biosens Bioelectron Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Hidrogéis Idioma: En Revista: Biosens Bioelectron Ano de publicação: 2023 Tipo de documento: Article