Your browser doesn't support javascript.
loading
Impact of height difference between coronary ostium and location of intracoronary pressure sensor on fractional flow reserve measurements.
Soh, Moon-Seung; Kim, Hangyul; Kang, Min Gyu; Lee, Hyo Jin; Lee, Seung Do; Hwang, Seok-Jae; Hwang, Jin-Yong; Kim, Kyehwan; Park, Jeong-Rang; Kim, Hye-Ree; Tahk, Seung-Jea; Yoon, Myeong-Ho; Lim, Hong-Seok; Koh, Jin-Sin.
Afiliação
  • Soh MS; Department of Cardiology, Ajou University School of Medicine, Suwon, Republic of Korea.
  • Kim H; Division of Cardiology, Department of Internal Medicine, Gyeongsang National University School of Medicine, Gyeongsang National University Hospital, Jinju, Republic of Korea.
  • Kang MG; Division of Cardiology, Department of Internal Medicine, Gyeongsang National University School of Medicine, Gyeongsang National University Hospital, Jinju, Republic of Korea.
  • Lee HJ; Division of Cardiology, Department of Internal Medicine, Gyeongsang National University School of Medicine, Gyeongsang National University Hospital, Jinju, Republic of Korea.
  • Lee SD; Division of Cardiology, Department of Internal Medicine, Gyeongsang National University School of Medicine, Gyeongsang National University Hospital, Jinju, Republic of Korea.
  • Hwang SJ; Division of Cardiology, Department of Internal Medicine, Gyeongsang National University School of Medicine, Gyeongsang National University Hospital, Jinju, Republic of Korea.
  • Hwang JY; Division of Cardiology, Department of Internal Medicine, Gyeongsang National University School of Medicine, Gyeongsang National University Hospital, Jinju, Republic of Korea.
  • Kim K; Division of Cardiology, Department of Internal Medicine, Gyeongsang National University School of Medicine, Gyeongsang National University Hospital, Jinju, Republic of Korea.
  • Park JR; Division of Cardiology, Department of Internal Medicine, Gyeongsang National University School of Medicine, Gyeongsang National University Hospital, Jinju, Republic of Korea.
  • Kim HR; Division of Cardiology, Department of Internal Medicine, Gyeongsang National University School of Medicine, Gyeongsang National University Hospital, Jinju, Republic of Korea.
  • Tahk SJ; Department of Cardiology, Ajou University School of Medicine, Suwon, Republic of Korea.
  • Yoon MH; Department of Cardiology, Ajou University School of Medicine, Suwon, Republic of Korea.
  • Lim HS; Department of Cardiology, Ajou University School of Medicine, Suwon, Republic of Korea.
  • Koh JS; Division of Cardiology, Department of Internal Medicine, Gyeongsang National University School of Medicine, Gyeongsang National University Hospital, Jinju, Republic of Korea.
PLoS One ; 18(8): e0289646, 2023.
Article em En | MEDLINE | ID: mdl-37616282
ABSTRACT

BACKGROUND:

During fractional flow reserve (FFR) measurements, distal coronary pressure (Pd) can be influenced by hydrostatic pressure changes resulting from the height difference (HD) between the coronary ostium and the location of the distal pressure sensor.

AIMS:

We investigated the effect of aortocoronary HD on the FFR measurements in each coronary artery.

METHODS:

In this retrospective cohort study, we analyzed 257 patients who underwent FFR measurements and coronary computed tomography (CCTA) within a year. Using CCTA, we measured HD as the vertical distance between the coronary ostium and a matched point of the distal coronary pressure sensor identified on coronary angiography.

RESULTS:

The location of the Pd sensor was higher than the coronary ostium in the left anterior descending artery (LAD) (-4.64 ± 1.15 cm) and lower than the coronary ostium in the left circumflex artery (LCX) (2.54 ± 1.05 cm) and right coronary artery (RCA) (2.03 ± 1.28 cm). The corrected FFR values by HD were higher in the LAD (0.78 ± 0.09 to 0.82 ± 0.09, P<0.01) and lower in the LCX and RCA than the original FFR values (0.87 ± 0.07 to 0.85 ± 0.08, P<0.01; 0.87 ± 0.10 to 0.86 ± 0.10, P<0.01, respectively). Using an FFR cut-off value of 0.8, the concordance rates between the FFR and corrected FFR values were 77.8%, 95.2%, and 100% in the LAD, LCX, and RCA, respectively.

CONCLUSION:

HD between the coronary ostium and the distal coronary pressure sensor may affect FFR measurements and FFR-guided treatment decisions for coronary artery disease.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doença da Artéria Coronariana / Reserva Fracionada de Fluxo Miocárdico Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies Limite: Humans Idioma: En Revista: PLoS One Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doença da Artéria Coronariana / Reserva Fracionada de Fluxo Miocárdico Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies Limite: Humans Idioma: En Revista: PLoS One Ano de publicação: 2023 Tipo de documento: Article