Accurate and sensitive measurements of free fatty acids (FFAs) in biological samples are valuable for diagnosing and prognosing diseases. In this study, an in-source microdroplet derivation strategy combined with high-resolution mass spectrometry was developed to analyze FFAs in lipid extracts of biological samples directly. FFAs were rapidly derivated with 2-picolylamine (PA) in the microdroplet which is derived by electrospray. With the proposed method, twelve typical FFAs were determined reliably with high sensitivity and acceptable linearities (R2 ≥ 0.94). The LODs and LOQs for the twelve FFAs were 9-76 pg mL-1 and 30-253 pg mL-1, respectively. The developed method was applied to analyze the alteration of FFAs in liver and kidney samples of rats induced by perfluorooctane sulfonate (PFOS) exposure. The good results demonstrate that the established analysis technique is dependable and has promising applications in detecting FFAs associated with complex biological samples.
Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Ácidos Graxos não Esterificados
/
Rim
Tipo de estudo:
Diagnostic_studies
Limite:
Animals
Idioma:
En
Revista:
Anal Chim Acta
Ano de publicação:
2023
Tipo de documento: