Your browser doesn't support javascript.
loading
Discriminative Dissolution Method Using the Open-Loop Configuration of the USP IV Apparatus to Compare Dissolution Profiles of Metoprolol Tartrate Immediate-Release Tablets: Use of Kinetic Parameters.
Solis-Cruz, Bruno; Hernandez-Patlan, Daniel; Morales Hipólito, Elvia A; Tellez-Isaias, Guillermo; Alcántara Pineda, Alejandro; López-Arellano, Raquel.
Afiliação
  • Solis-Cruz B; Laboratory 5: LEDEFAR, Multidisciplinary Research Unit, Superior Studies Faculty at Cuautitlan (FESC), National Autonomous University of Mexico (UNAM), Cuautitlan Izcalli 54714, Mexico.
  • Hernandez-Patlan D; Nanotechnology Engineering Division, Polytechnic University of the Valley of Mexico, Tultitlan 54910, Mexico.
  • Morales Hipólito EA; Laboratory 5: LEDEFAR, Multidisciplinary Research Unit, Superior Studies Faculty at Cuautitlan (FESC), National Autonomous University of Mexico (UNAM), Cuautitlan Izcalli 54714, Mexico.
  • Tellez-Isaias G; Nanotechnology Engineering Division, Polytechnic University of the Valley of Mexico, Tultitlan 54910, Mexico.
  • Alcántara Pineda A; Laboratory 5: LEDEFAR, Multidisciplinary Research Unit, Superior Studies Faculty at Cuautitlan (FESC), National Autonomous University of Mexico (UNAM), Cuautitlan Izcalli 54714, Mexico.
  • López-Arellano R; Division of Agriculture, Department of Poultry Science, University of Arkansas, Fayetteville, AR 72701, USA.
Pharmaceutics ; 15(9)2023 Aug 24.
Article em En | MEDLINE | ID: mdl-37765161
ABSTRACT
The use of the USP IV apparatus (flow-through cell) has gained acceptance in recent years due to its versatility and ability to discriminate due to its hydrodynamic conditions. Therefore, the objective of the present study was to develop a discriminative dissolution method in the USP IV apparatus using the open-loop configuration, as well as to propose a method to compare non-cumulative dissolution profiles obtained in the open-loop configuration considering kinetic parameters and validate its predictive power through its comparison with independent and dependent methods using five commercial immediate-release tablet drugs (one reference drug and four generic drugs) of metoprolol tartrate as a model drug. The comparison of the non-accumulated dissolution profiles consisted of determining the geometric ratio of Cmax, AUC0∞, AUC0Cmax, and Tmax (kinetic parameters) of the generic/reference drugs, whereby generic drugs "C" and "D" presented the highest probability of similarity since their 90% confidence intervals were included, or they were very close to the acceptance interval (80.00-125.00%). These results were consistent with the f2, bootstrap f2, and dissolution efficiency approaches (independent models). In conclusion, the proposed comparison method can be an important tool to establish similarity in dissolution profiles and to facilitate the development/selection of new formulations and positively ensure bioequivalence in clinical studies.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Revista: Pharmaceutics Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Revista: Pharmaceutics Ano de publicação: 2023 Tipo de documento: Article