Your browser doesn't support javascript.
loading
Combining Near-Infrared Spectroscopy and Heart Rate Variability Derived Thresholds to Estimate the Critical Intensity of Exercise.
Fleitas-Paniagua, Pablo R; de Almeida Azevedo, Rafael; Trpcic, Mackenzie; Murias, Juan M; Rogers, Bruce.
Afiliação
  • Fleitas-Paniagua PR; Faculty of Kinesiology, University of Calgary, Calgary, Canada.
  • de Almeida Azevedo R; Faculty of Kinesiology, University of Calgary, Calgary, Canada.
  • Trpcic M; Faculty of Kinesiology, University of Calgary, Calgary, Canada.
  • Murias JM; Faculty of Kinesiology, University of Calgary, Calgary, Canada.
  • Rogers B; College of Health and Life Sciences, Hamad Bin Khalifa University, Doha, Qatar; and.
J Strength Cond Res ; 38(1): e16-e24, 2024 Jan 01.
Article em En | MEDLINE | ID: mdl-37815285
ABSTRACT
ABSTRACT Fleitas-Paniagua, PR, de Almeida Azevedo, R, Trpcic, M, Murias, JM, and Rogers, B. Combining near-infrared spectroscopy and heart rate variability derived thresholds to estimate the critical intensity of exercise. J Strength Cond Res 38(1) e16-e24, 2024-Critical intensity determination often requires costly tools and several testing sessions. Alternative approaches display relatively large individual variation. Therefore, simpler estimations with improved precision are needed. This study evaluated whether averaging the heart rate (HR) and oxygen uptake (V̇O 2 ) responses associated with the muscle deoxyhemoglobin concentration breakpoint ([HHb] BP ) and the heart rate variability (HRV) given by the detrended fluctuation analysis second threshold (HRVT2) during ramp incremental (RI) test improved the accuracy of identifying the HR and V̇O 2 at the respiratory compensation point (RCP). Ten female and 11 male recreationally trained subjects performed a 15 W·minute -1 RI test. Gas exchange, near-infrared spectroscopy (NIRS), and RR interval were recorded to assess the RCP, [HHb] BP , and HRVT2. Heart rate (mean ± SD 158 ± 14, 156 ± 13, 160 ± 14 and, 158 ± 12 bpm) and V̇O 2 (3.08 ± 0.69, 2.98 ± 0.58, 3.06 ± 0.65, and 3.02 ± 0.60 L·minute -1 ) at the RCP, [HHb] BP , HRVT2, and HRVT2&[HHb] BP average (H&H Av ), respectively, were not significantly different ( p > 0.05). The linear relationship between H&H Av and RCP was higher compared with the relationship between [HHb] BP vs RCP and HRVT2 vs RCP for both HR ( r = 0.85; r = 0.73; r = 0.79, p > 0.05) and V̇O 2 ( r = 0.94; r = 0.93; r = 0.91, p > 0.05). Intraclass correlation between RCP, [HHb] BP , HRVT2, and H&H AV was 0.93 for V̇O 2 and 0.79 for HR. The [HHb] BP and the HRVT2 independently provided V̇O 2 and HR responses that strongly agreed with those at the RCP. Combining [HHb] BP and the HRVT2 resulted in estimations of the V̇O 2 and HR at the RCP that displayed smaller variability compared with each modality alone.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Consumo de Oxigênio / Espectroscopia de Luz Próxima ao Infravermelho Limite: Female / Humans / Male Idioma: En Revista: J Strength Cond Res Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Consumo de Oxigênio / Espectroscopia de Luz Próxima ao Infravermelho Limite: Female / Humans / Male Idioma: En Revista: J Strength Cond Res Ano de publicação: 2024 Tipo de documento: Article