Your browser doesn't support javascript.
loading
Use of the advisor™ HD Grid mapping catheter in transcatheter ablation of atrial arrhythmias in palliated CHD and children without CHD.
Balli, Sevket; Kanlioglu, Pinar; Altin, Hüsnü F.
Afiliação
  • Balli S; Department of Pediatric Cardiology, Dr. Siyami Ersek Thoracic and Cardiovascular Surgery Training & Research Hospital, University of Health Sciences, Istanbul, Turkey.
  • Kanlioglu P; Department of Pediatric Cardiology, Dr. Siyami Ersek Thoracic and Cardiovascular Surgery Training & Research Hospital, University of Health Sciences, Istanbul, Turkey.
  • Altin HF; Department of Pediatric Cardiovascular Surgery, Dr. Siyami Ersek Thoracic and Cardiovascular Surgery Training & Research Hospital, University of Health Sciences, Istanbul, Turkey.
Cardiol Young ; 34(4): 776-781, 2024 Apr.
Article em En | MEDLINE | ID: mdl-37822189
ABSTRACT

OBJECTIVE:

In this study, we describe our experience utilising Advisor™ High Density (HD) Grid mapping catheter in transcatheter ablation of intraatrial re-entrant and focal atrial tachycardias with or without CHD.

METHODS:

Forty-five consecutive patients with intraatrial re-entrant and focal atrial tachycardia who underwent a transcatheter ablation procedure by using Advisor™ HD Grid mapping catheter and high-density mapping system in our hospital from January 2017 to January 2023 were included into the study.

RESULTS:

The mean age of the patients was 14.2 ± 7.3 years (6-32 years), and the mean weight was 48.3 ± 16.2 kg (22-83 kg). Of the total 45 patients, 21 were intraatrial re-entrant tachycardia and 25 were focal atrial tachycardia. Of the 21 re-entrant circuits, 15 were classified as cavotricuspid isthmus-dependent and 5 were non-cavotricuspid isthmus-dependent. In one patient, two re-entrant circuits were identified. A transbaffle ablation was successfully performed from the left atrium in one patient. Of the 25 focal atrial tachycardia, 19 were from right atrium and 6 were from left atrium. A cryoablation was performed in only one patient and radiofrequency ablation in others. The mean procedure time was 180 ± 64 minutes. The mean follow-up period was 69.3 ± 35.3 months. Acute success was 95.5%. Recurrence was noted in two patients (4.4%).

CONCLUSION:

Advisor™ HD Grid mapping catheter was found to be safe and achieved an acceptable success in transcatheter ablation of patients with intraatrial re-entrant tachycardia and focal atrial tachycardias.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Taquicardia Atrial Ectópica / Ablação por Cateter Limite: Adolescent / Adult / Child / Humans Idioma: En Revista: Cardiol Young Ano de publicação: 2024 Tipo de documento: Article