Central corneal distortion after small-incision lenticule extraction.
J Cataract Refract Surg
; 49(11): 1183-1186, 2023 11 01.
Article
em En
| MEDLINE
| ID: mdl-37867287
A 33-year-old woman with a prior history of small-incision lenticule extraction (SMILE) presented with gradual deterioration of vision in her right eye since the surgery. She had undergone bilateral SMILE for myopic correction (-7.00 diopters [D] in the right eye and -6.00 D in the left eye) 3 weeks prior. SMILE was performed with a Zeiss VisuMax femtosecond laser system, with a cap thickness of 120 µm, a cap diameter of 7.50 mm, and a lenticule diameter of 6.50 mm. At the completion of the surgery, loose epithelium was noted at the SMILE incision bilaterally, and bandage contact lenses were placed in both eyes. On the first postoperative day, the patient's uncorrected distance visual acuity (UDVA) was 20/40 in both eyes. The bandage lenses were removed from both eyes, with the epithelium intact. At the first-week postoperative visit, her visual acuity was recorded as 20/30 in the right eye and 20/20 in the left eye. She noticed her vision in the right eye was not as sharp as that in her left eye. She denied experiencing any pain, redness, or ocular surface irritations. She was advised to return to the clinic for a 1-month postoperative visit and continue with aggressive lubrication in both eyes. However, a week later, the patient returned for an emergency visit, citing significant central visual distortion in the right eye and difficulty working on the computer. At this visit, her UDVA and corrected distance visual acuity (CDVA) was 20/50 in the right eye and 20/15 in the left eye at both near and far distances. A slitlamp examination revealed mild central changes in the right eye. She once again denied any pain, redness, or irritation. She was advised to continue with artificial tears and return to the office in 1 week for further observation of the central distortion in her right eye. Upon returning to the clinic at the third postoperative week, the patient still complained of central visual changes in the right eye, with a visual acuity of 20/70. Further slitlamp examination revealed a nonspecific central haze in the same eye, but there was no corneal staining or signs of epithelial defects. Anterior segment ocular coherence tomography (AS-OCT) and NIDEK topography were performed, showing the same central distortion in the right eye (Figures 1 and 2JOURNAL/jcrs/04.03/02158034-202311000-00016/figure1/v/2023-10-18T004638Z/r/image-tiffJOURNAL/jcrs/04.03/02158034-202311000-00016/figure2/v/2023-10-18T004638Z/r/image-tiff). Based on the examination and images provided, what is your working medical diagnosis? What other medical conditions are in your differential diagnosis? What medical and/or surgical interventions would you recommend, if any?
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Refração Ocular
/
Cirurgia da Córnea a Laser
Limite:
Adult
/
Female
/
Humans
Idioma:
En
Revista:
J Cataract Refract Surg
Ano de publicação:
2023
Tipo de documento:
Article