Your browser doesn't support javascript.
loading
Repeatability of Quantitative Knee Cartilage T1 , T2 , and T Mapping With 3D-MRI Fingerprinting.
Zhang, Xiaoxia; de Moura, Hector L; Monga, Anmol; Zibetti, Marcelo V W; Kijowski, Richard; Regatte, Ravinder R.
Afiliação
  • Zhang X; Center of Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, New York, USA.
  • de Moura HL; Center of Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, New York, USA.
  • Monga A; Center of Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, New York, USA.
  • Zibetti MVW; Center of Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, New York, USA.
  • Kijowski R; Center of Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, New York, USA.
  • Regatte RR; Center of Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, New York, USA.
J Magn Reson Imaging ; 2023 Oct 26.
Article em En | MEDLINE | ID: mdl-37885320
BACKGROUND: Three-dimensional MR fingerprinting (3D-MRF) techniques have been recently described for simultaneous multiparametric mapping of knee cartilage. However, investigation of repeatability remains limited. PURPOSE: To assess the intra-day and inter-day repeatabilities of knee cartilage T1 , T2 , and T1ρ maps using a 3D-MRF sequence for simultaneous measurement. STUDY TYPE: Prospective. SUBJECTS: Fourteen healthy subjects (35.4 ± 9.3 years, eight males), scanned on Day 1 and Day 7. FIELD STRENGTH/SEQUENCE: 3 T/3D-MRF, T1 , T2 , and T1ρ maps. ASSESSMENT: The acquisition of 3D-MRF cartilage (simultaneous acquisition of T1 , T2 , and T1ρ maps) were acquired using a dictionary pattern-matching approach. Conventional cartilage T1 , T2 , and T1ρ maps were acquired using variable flip angles and a modified 3D-Turbo-Flash sequence with different echo and spin-lock times, respectively, and were fitted using mono-exponential models. Each sequence was acquired on Day 1 and Day 7 with two scans on each day. STATISTICAL TESTS: The mean and SD for cartilage T1 , T2 , and T1ρ were calculated in five manually segmented regions of interest (ROIs), including lateral femur, lateral tibia, medial femur, medial tibia, and patella cartilages. Intra-subject and inter-subject repeatabilities were assessed using coefficient of variation (CV) and intra-class correlation coefficient (ICC), respectively, on the same day and among different days. Regression and Bland-Altman analysis were performed to compare maps between the conventional and 3D-MRF sequences. RESULTS: The CV in all ROIs was lower than 7.4%, 8.4%, and 7.5% and the ICC was higher than 0.56, 0.51, and 0.52 for cartilage T1 , T2 , and T1ρ , respectively. The MRF results had a good agreement with the conventional methods with a linear regression slope >0.61 and R2 > 0.59. CONCLUSION: The 3D-MRF sequence had high intra-subject and inter-subject repeatabilities for simultaneously measuring knee cartilage T1 , T2 , and T1ρ with good agreement with conventional sequences. EVIDENCE LEVEL: 1 TECHNICAL EFFICACY: Stage 1.