Your browser doesn't support javascript.
loading
Accuracy of computer-assisted dynamic navigation when performing coronectomy of the mandibular third molar: A pilot study.
Zhang, Hao-Xiang; Yan, Zi-Yu; Cui, Nian-Hui; Sun, Feng; Wu, Bin-Zhang.
Afiliação
  • Zhang HX; Department of Oral and Maxillofacial Surgery, Peking University School and Hospital of Stomatology & National Center for Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices, Beijing, PR
  • Yan ZY; Department of Oral and Maxillofacial Surgery, Peking University School and Hospital of Stomatology & National Center for Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices, Beijing, PR
  • Cui NH; Department of Oral and Maxillofacial Surgery, Peking University School and Hospital of Stomatology & National Center for Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices, Beijing, PR
  • Sun F; First Clinical Division, Peking University School and Hospital of Stomatology & National Center for Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices, Beijing, PR China.
  • Wu BZ; First Clinical Division, Peking University School and Hospital of Stomatology & National Center for Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices, Beijing, PR China. Electronic add
J Dent ; 139: 104762, 2023 12.
Article em En | MEDLINE | ID: mdl-37898432
OBJECTIVES: The study represents a preliminary evaluation of the accuracy of the dynamic navigation system (DNS) in coronectomy of the mandibular third molar (M3M). METHODS: The study included participants with an impacted M3M near the inferior alveolar canal. The coronectomy planes were designed before the surgery using cone-beam computed tomography (CBCT) imaging data and then loaded into the DNS program. Intraoperatively, the navigation system was used to guide the complete removal of the target crown. Postoperative CBCT imaging was used to assess any three-dimensional deviations of the actual postoperative from the planned preoperative section planes for each patient. RESULTS: A total of 12 patients (13 teeth) were included. The root mean square (RMS) deviation of the preoperatively designed plane from the actual postoperative surface was 0.69 ± 0.21 mm, with a maximum of 1.45 ± 0.83/-1.87 ± 0.63 mm deviation. The areas with distance deviations < 1 mm, 1-2 mm, and 2-3 mm were 71.97 ± 5.72 %, 22.96 ± 6.57 %, and 4.52 ± 2.28 %, respectively. Most patients showed extremely high convexity of the surface area located in the mesial region adjacent to the base of the extraction socket. There was no observable evidence of scratching of the buccolingual bone plate at the base of the extraction socket by the handpiece drill. CONCLUSIONS: These results provide preliminary support for the use of DNS-based techniques when extracting M3M using a buccal approach. This would improve the accuracy of coronectomy and reduce the potiential damage to the surrounding tissue. CLINICAL SIGNIFICANCE: DNS is effective for guiding coronectomy.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Traumatismos do Nervo Trigêmeo / Dente Serotino Limite: Humans Idioma: En Revista: J Dent Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Traumatismos do Nervo Trigêmeo / Dente Serotino Limite: Humans Idioma: En Revista: J Dent Ano de publicação: 2023 Tipo de documento: Article