Your browser doesn't support javascript.
loading
Remote assessment of pelvic kinematics during single leg squat using smartphone sensors: Between-day reliability and identification of acute changes in motor performance.
Devecchi, Valter; Saunders, Michelle; Galaiya, Sajni; Shaw, Millie; Gallina, Alessio.
Afiliação
  • Devecchi V; School of Sport, Exercise and Rehabilitation Sciences, University of Birmingham, Birmingham, United Kingdom.
  • Saunders M; School of Sport, Exercise and Rehabilitation Sciences, University of Birmingham, Birmingham, United Kingdom.
  • Galaiya S; School of Sport, Exercise and Rehabilitation Sciences, University of Birmingham, Birmingham, United Kingdom.
  • Shaw M; School of Sport, Exercise and Rehabilitation Sciences, University of Birmingham, Birmingham, United Kingdom.
  • Gallina A; School of Sport, Exercise and Rehabilitation Sciences, University of Birmingham, Birmingham, United Kingdom.
PLoS One ; 18(11): e0288760, 2023.
Article em En | MEDLINE | ID: mdl-37992071
ABSTRACT
The biomechanical assessment of pelvic kinematics during a single leg squat (SLS) commonly relies on expensive equipment, which precludes its wider implementation in ecological settings. Smartphone sensors could represent an effective solution to objectively quantify pelvic kinematics remotely, but their measure properties need to be evaluated before advocating their use in practice. This study aimed to assess whether measures of pelvic kinematics collected remotely using smartphones during SLS are repeatable between days, and if changes in pelvic kinematics can be identified during an endurance task. Thirty-three healthy young adults were tested remotely on two different days using their own smartphones placed on the lumbosacral region. Pelvic orientation and acceleration were collected during three sets of seven SLS and an endurance task of twenty consecutive SLS. The intersession reliability was assessed using Intraclass Correlation Coefficient (ICC2,k), Standard Error of Measurement, and Minimal Detectable Change. T-tests were used to identify pelvic kinematics changes during the endurance task and to assess between-day bias. Measures of pelvic orientation and frequency features of the acceleration signals showed good to excellent reliability (multiple ICC2,k ≥ 0.79), and a shift of the power spectrum to lower frequencies on the second day (multiple p<0.05). The endurance task resulted in larger contralateral pelvic drop and rotation (multiple p<0.05) and increased spectral entropy (multiple p<0.05). Our findings demonstrate that reliable measures of pelvic kinematics can be obtained remotely using participants' smartphones during SLS. Smartphone sensors can also identify changes in motor control, such as contralateral pelvic drop during an endurance task.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Smartphone / Perna (Membro) Limite: Adult / Humans Idioma: En Revista: PLoS One Ano de publicação: 2023 Tipo de documento: Article