Comparison of different techniques for prehospital cervical spine immobilization: Biomechanical measurements with a wireless motion capture system.
PLoS One
; 18(11): e0292300, 2023.
Article
em En
| MEDLINE
| ID: mdl-38015902
BACKGROUND: Various rescue techniques are used for the prehospital transport of trauma patients. This study compares different techniques in terms of immobilization of the cervical spine and the rescue time. METHODS: A wireless motion capture system (Xsens Technologies, Enschede, The Netherlands) was used to record motion in three-dimensional space and the rescue time in a standardized environment. Immobilization was performed by applying different techniques through different teams of trained paramedics and physicians. All tests were performed on the set course, starting with the test person lying on the floor and ending with the test person lying on an ambulance cot ready to be loaded into an ambulance. Six different settings for rescue techniques were examined: rescue sheet with/without rigid cervical collar (P1S1, P1S0), vacuum mattress and scoop stretcher with/without rigid cervical collar (P2S1, P2S0), and long spinal board with/without rigid cervical collar (P3S1, P3S0). Four time intervals were defined: the time interval in which the rigid cervical collar is applied (T0), the time interval in which the test person is positioned on rescue sheet, vacuum mattress and scoop stretcher, or long spinal board (T1), the time interval in which the test person is carried to the ambulance cot (T2), and the time interval in which the ambulance cot is rolled to the ambulance (T3). An ANOVA was performed to compare the different techniques. RESULTS: During the simulated extrication procedures, a rigid cervical collar provided biomechanical stability at all angles with hardly any loss of time (mean angle ranges during T1: axial rotation P1S0 vs P1S1 p<0.0001, P2S0 vs P2S1 p<0.0001, P3S0 vs P3S1 p<0.0001; lateral bending P1S0 vs P1S1 p = 0.0263, P2S0 vs P2S1 p<0.0001, P3S0 vs P3S1 p<0.0001; flexion/extension P1S0 vs P1S1 p = 0.0023, P2S0 vs P2S1 p<0.0001). Of the three techniques examined, the scoop stretcher and vacuum mattress were best for reducing lateral bending in the frontal plane (mean angle ranges during T1: P2S1 vs P3S1 p = 0.0333; P2S0 vs P3S0 p = 0.0123) as well as flexion and extension in the sagittal plane (mean angle ranges during T2: P1S1 vs P2S1 p<0.0001; P1S0 vs P2S0 p<0.0001). On the other hand, the rescue sheet was clearly superior in terms of time (total duration P1S0 vs P2S0 p<0.001, P1S1 vs P2S1 p<0.001, P1S0 vs P3S0 p<0.001, P1S1 vs P3S1 p<0.001) but was always associated with significantly larger angular ranges of the cervical spine during the procedure. Therefore, the choice of technique depends on various factors such as the rescue time, the available personnel, as well as the severity of the suspected instability.
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Macas
/
Imobilização
Limite:
Humans
Idioma:
En
Revista:
PLoS One
Ano de publicação:
2023
Tipo de documento:
Article