Rapid detection of hydrogen using narrow bandwidth fiber-optic spectral combs with a low limit of detection.
Opt Express ; 31(22): 35616-35623, 2023 Oct 23.
Article em En | MEDLINE | ID: mdl-38017728
ABSTRACT
The all-fiber detection solutions are the key technology to detecting hydrogen leakage in time because of the low explosive limit of the hydrogen-air mixture gas. However, most of the fiber-optic-based hydrogen sensing platforms must disrupt their structure to achieve a special architecture for interacting with the hydrogen. Here, we report a promising non-damaged structure of fiber-optic narrow bandwidth spectral combs, that can be developed to determine the refractive change as low as 10-5 using its cut-off cladding resonance mode. Such high performance of response for the refractive index induces a rapid detection of hydrogen after a proper thickness of palladium was deposited on the device. An average response time of hydrogen of 4 min with a low limit of detection of 348 ppm was achieved. It is demonstrated that these narrow bandwidth fiber-optic resonance combs can be used for gas detection after being combined with functional materials.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Opt Express Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Opt Express Ano de publicação: 2023 Tipo de documento: Article