Your browser doesn't support javascript.
loading
Low-cross-talk and thermo-insensitive CWDM (de)multiplexer assisted with compact MZIs and slot waveguides.
Appl Opt ; 62(33): 8931-8938, 2023 Nov 20.
Article em En | MEDLINE | ID: mdl-38038040
ABSTRACT
A low-cross-talk and thermo-insensitive 1×4 coarse wavelength-division multiplexing device is proposed on the silicon-on-insulator platform with the help of compact Mach-Zehnder interferometers (MZIs) and slot waveguides. The compact MZIs are used to achieve wavelength-insensitive power splitting. In the phase shifters, the trade-off between the opposite thermo-optical coefficients of the Si core and SU8 cladding in the slot waveguide is used to overcome the strong thermo-optic effect of silicon. The simulated results show that the cross talk is less than -20d B at central wavelengths and the temperature-dependent wavelength shift is reduced to ∼4.7p m/∘ C. For the four channels, the 1-dB and 3-dB bandwidths are ∼14n m and ∼18n m, respectively.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Appl Opt Ano de publicação: 2023 Tipo de documento: Article