Your browser doesn't support javascript.
loading
A Couch Mounted Smartphone-based Motion Monitoring System for Radiation Therapy.
Capaldi, Dante P I; Axente, Marian; Yu, Amy S; Prionas, Nicolas D; Hirata, Emily; Nano, Tomi F.
Afiliação
  • Capaldi DPI; San Francisco (UCSF) Comprehensive Cancer Center, University of California, San Francisco, California.
  • Axente M; Department of Radiation Oncology, Emory University School of Medicine, Atlanta, Georgia.
  • Yu AS; Department of Radiation Oncology, School of Medicine, Stanford University, Stanford, California.
  • Prionas ND; San Francisco (UCSF) Comprehensive Cancer Center, University of California, San Francisco, California.
  • Hirata E; San Francisco (UCSF) Comprehensive Cancer Center, University of California, San Francisco, California.
  • Nano TF; San Francisco (UCSF) Comprehensive Cancer Center, University of California, San Francisco, California. Electronic address: tomi.nano@ucsf.edu.
Pract Radiat Oncol ; 14(2): 161-170, 2024.
Article em En | MEDLINE | ID: mdl-38052299
ABSTRACT

PURPOSE:

Surface-guided radiation-therapy (SGRT) systems are being adopted into clinical practice for patient setup and motion monitoring. However, commercial systems remain cost prohibitive to resource-limited clinics around the world. Our aim is to develop and validate a smartphone-based application using LiDAR cameras (such as on recent Apple iOS devices) for facilitating SGRT in low-resource centers. The proposed SGRT application was tested at multiple institutions and validated using phantoms and volunteers against various commercial systems to demonstrate feasibility. METHODS AND MATERIALS An iOS application was developed in Xcode and written in Swift using the Augmented-Reality (AR) Kit and implemented on an Apple iPhone 13 Pro with a built-in LiDAR camera. The application contains multiple features 1) visualization of both the camera and depth video feeds (at a ∼60Hz sample-frequency), 2) region-of-interest (ROI) selection over the patient's anatomy where motion is measured, 3) chart displaying the average motion over time in the ROI, and 4) saving/exporting the motion traces and surface map over the ROI for further analysis. The iOS application was tested to evaluate depth measurement accuracy for 1) different angled surfaces, 2) different field-of-views over different distances, and 3) similarity to a commercially available SGRT systems (Vision RT AlignRT and Varian IDENTIFY) with motion phantoms and healthy volunteers across 3 institutions. Measurements were analyzed using linear-regressions and Bland-Altman analysis.

RESULTS:

Compared with the clinical system measurements (reference), the iOS application showed excellent agreement for depth (r = 1.000, P < .0001; bias = -0.07±0.24 cm) and angle (r = 1.000, P < .0001; bias = 0.02±0.69°) measurements. For free-breathing traces, the iOS application was significantly correlated to phantom motion (institute 1 r = 0.99, P < .0001; bias =-0.003±0.03 cm; institute 2 r = 0.98, P < .0001; bias = -0.001±0.10 cm; institute 3 r = 0.97, P < .0001; bias = 0.04±0.06 cm) and healthy volunteer motion (institute 1 r = 0.98, P < .0001; bias = -0.008±0.06 cm; institute 2 r = 0.99, P < .0001; bias = -0.007±0.12 cm; institute 3 r = 0.99, P < .0001; bias = -0.001±0.04 cm).

CONCLUSIONS:

The proposed approach using a smartphone-based application provides a low-cost platform that could improve access to surface-guided radiation therapy accounting for motion.