Your browser doesn't support javascript.
loading
Preliminary Exploration of Pseudo-CT-Based Attenuation Correction for Simultaneous PET/MRI Brain Imaging in Nonhuman Primates.
Yoo, Chi-Hyeon; DuBois, Jonathan M; Wang, Lu; Tang, Yongjin; Hou, Lu; Xu, Hao; Chen, Jiahui; Liang, Steven H; Izquierdo-Garcia, David; Wey, Hsiao-Ying.
Afiliação
  • Yoo CH; Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Charlestown 02129, United States.
  • DuBois JM; Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Charlestown 02129, United States.
  • Wang L; Department of Nuclear Medicine and PET/CT-MRI Center, The First Affiliated Hospital of Jinan University, Guangzhou 510630, China.
  • Tang Y; Department of Nuclear Medicine and PET/CT-MRI Center, The First Affiliated Hospital of Jinan University, Guangzhou 510630, China.
  • Hou L; Department of Nuclear Medicine and PET/CT-MRI Center, The First Affiliated Hospital of Jinan University, Guangzhou 510630, China.
  • Xu H; Department of Nuclear Medicine and PET/CT-MRI Center, The First Affiliated Hospital of Jinan University, Guangzhou 510630, China.
  • Chen J; Division of Nuclear Medicine and Molecular Imaging, Center for Advanced Medical Imaging Sciences, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts 02114, United States.
  • Liang SH; Division of Nuclear Medicine and Molecular Imaging, Center for Advanced Medical Imaging Sciences, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts 02114, United States.
  • Izquierdo-Garcia D; Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Charlestown 02129, United States.
  • Wey HY; Harvard-MIT Division of Health Sciences and Technology, Cambridge, Massachusetts 02139, United States.
ACS Omega ; 8(48): 45438-45446, 2023 Dec 05.
Article em En | MEDLINE | ID: mdl-38075761
ABSTRACT
This study aimed to develop a template-based attenuation correction (AC) for the nonhuman primate (NHP) brain. We evaluated the effects of AC on positron emission tomography (PET) data quantification with two experimental paradigms by comparing the quantitative outcomes obtained using a segmentation-based AC versus template-based AC. Population-based atlas was generated from ten adult rhesus macaques. Bolus experiments using [18F]PF-06455943 and a bolus-infusion experiment using [11C]OMAR were performed on a 3T Siemens PET/magnetic resonance-imaging (MRI). PET data were reconstructed with either µ map obtained from the segmentation-based AC or template-based AC. The standard uptake value (SUV), volume of distribution (VT), or percentage occupancy of rimonabant were calculated for [18F]PF-06455943 and [11C]OMAR PET, respectively. The leave-one-out cross-validation showed that the absolute percentage differences were 2.54 ± 2.86% for all region of interests. The segmentation-based AC had a lower SUV and VT (∼10%) of [18F]PF-06455943 than the template-based method. The estimated occupancy was higher in the template-based method compared to the segmentation-based AC in the bolus-infusion study. However, future studies may be needed if a different reference tissue is selected for data quantification. Our template-based AC approach was successfully developed and applied to the NHP brain. One limitation of this study was that validation was performed by comparing two different MR-based AC approaches without validating against AC methods based on computed tomography (CT).

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: ACS Omega Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: ACS Omega Ano de publicação: 2023 Tipo de documento: Article