Your browser doesn't support javascript.
loading
Simultaneous Detection and Decontamination of Dichromate Ions: The Fluorescence Response and Photocatalysis of Thiadiazole-Modified Zr-Metal-Organic Frameworks.
Hu, Xiaojun; Zhang, Yajing; Liu, Hezhen; Zhan, Minghui; Chen, Jie; Liu, Zhenmin; Chen, Hongxia.
Afiliação
  • Hu X; State Key Laboratory of Dairy Biotechnology, Shanghai Engineering Research Center of Dairy Biotechnology, Dairy Research Institute, Bright Dairy & Food Co., Ltd., Shanghai 200436, China.
  • Zhang Y; Center for Molecular Recognition and Biosensing, School of Life Sciences, Shanghai University, Shanghai 200444, PR China.
  • Liu H; Qian Weichang College, Shanghai University, Shanghai 200444, PR China.
  • Zhan M; Center for Molecular Recognition and Biosensing, School of Life Sciences, Shanghai University, Shanghai 200444, PR China.
  • Chen J; Center for Molecular Recognition and Biosensing, School of Life Sciences, Shanghai University, Shanghai 200444, PR China.
  • Liu Z; Center for Molecular Recognition and Biosensing, School of Life Sciences, Shanghai University, Shanghai 200444, PR China.
  • Chen H; State Key Laboratory of Dairy Biotechnology, Shanghai Engineering Research Center of Dairy Biotechnology, Dairy Research Institute, Bright Dairy & Food Co., Ltd., Shanghai 200436, China.
J Agric Food Chem ; 71(51): 20575-20584, 2023 Dec 27.
Article em En | MEDLINE | ID: mdl-38105633
ABSTRACT
The simultaneous analysis and removal of highly toxic hexavalent chromium (Cr (VI)) in contaminated water via an easy method remain a serious task. Based on the guidance of bibliometric analysis, a thiadiazole ligand-modified zirconium metal-organic framework (Zr-MOF) heralds a new and simple approach to Cr (VI) treatment. The concentration can be determined by fluorescence quenching with a low detection limit of 1.4 µM and a high quenching constant of 6.88 × 103 M-1. For the sensing mechanism, the fluorescence intensity of the Zr-MOF decreased rapidly due to the competition of Cr (VI) with the Zr-MOF for absorption excitation energy and the induction of Zr-MOF aggregation. The analysis system also displayed satisfactory stability and applicability. Apart from sensing application, Zr-MOF can convert Cr (VI) to Cr (III), and the reduction rate constant was 0.004 min-1 under irradiation. Therefore, the bifunctional Zr-MOF provided a potential application method for controlling the pollution caused by Cr (VI) in wastewater.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Estruturas Metalorgânicas Idioma: En Revista: J Agric Food Chem Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Estruturas Metalorgânicas Idioma: En Revista: J Agric Food Chem Ano de publicação: 2023 Tipo de documento: Article