Breast cancer detection accuracy of AI in an entire screening population: a retrospective, multicentre study.
Elhakim, Mohammad Talal; Stougaard, Sarah Wordenskjold; Graumann, Ole; Nielsen, Mads; Lång, Kristina; Gerke, Oke; Larsen, Lisbet Brønsro; Rasmussen, Benjamin Schnack Brandt.
Afiliação
  • Elhakim MT; Department of Radiology, Odense University Hospital, Kløvervaenget 47, Entrance 27, Ground floor, 5000, Odense C, Denmark. mte@rsyd.dk.
  • Stougaard SW; Department of Clinical Research, University of Southern Denmark, Kløvervaenget 10, Entrance 112, 2nd floor, 5000, Odense C, Denmark. mte@rsyd.dk.
  • Graumann O; Department of Clinical Research, University of Southern Denmark, Kløvervaenget 10, Entrance 112, 2nd floor, 5000, Odense C, Denmark.
  • Nielsen M; Department of Clinical Research, University of Southern Denmark, Kløvervaenget 10, Entrance 112, 2nd floor, 5000, Odense C, Denmark.
  • Lång K; Department of Radiology, Aarhus University Hospital, Palle Juul-Jensens Blvd. 99, 8200, Aarhus N, Denmark.
  • Gerke O; Department of Clinical Research, Aarhus University, Palle Juul-Jensens Blvd. 99, 8200, Aarhus N, Denmark.
  • Larsen LB; Department of Computer Science, University of Copenhagen, Universitetsparken 1, 2100, København Ø, Denmark.
  • Rasmussen BSB; Department of Translational Medicine, Lund University, Inga Maria Nilssons gata 47, SE-20502, Malmö, Sweden.
Cancer Imaging ; 23(1): 127, 2023 Dec 20.
Article em En | MEDLINE | ID: mdl-38124111
ABSTRACT

BACKGROUND:

Artificial intelligence (AI) systems are proposed as a replacement of the first reader in double reading within mammography screening. We aimed to assess cancer detection accuracy of an AI system in a Danish screening population.

METHODS:

We retrieved a consecutive screening cohort from the Region of Southern Denmark including all participating women between Aug 4, 2014, and August 15, 2018. Screening mammograms were processed by a commercial AI system and detection accuracy was evaluated in two scenarios, Standalone AI and AI-integrated screening replacing first reader, with first reader and double reading with arbitration (combined reading) as comparators, respectively. Two AI-score cut-off points were applied by matching at mean first reader sensitivity (AIsens) and specificity (AIspec). Reference standard was histopathology-proven breast cancer or cancer-free follow-up within 24 months. Coprimary endpoints were sensitivity and specificity, and secondary endpoints were positive predictive value (PPV), negative predictive value (NPV), recall rate, and arbitration rate. Accuracy estimates were calculated using McNemar's test or exact binomial test.

RESULTS:

Out of 272,008 screening mammograms from 158,732 women, 257,671 (94.7%) with adequate image data were included in the final analyses. Sensitivity and specificity were 63.7% (95% CI 61.6%-65.8%) and 97.8% (97.7-97.8%) for first reader, and 73.9% (72.0-75.8%) and 97.9% (97.9-98.0%) for combined reading, respectively. Standalone AIsens showed a lower specificity (-1.3%) and PPV (-6.1%), and a higher recall rate (+ 1.3%) compared to first reader (p < 0.0001 for all), while Standalone AIspec had a lower sensitivity (-5.1%; p < 0.0001), PPV (-1.3%; p = 0.01) and NPV (-0.04%; p = 0.0002). Compared to combined reading, Integrated AIsens achieved higher sensitivity (+ 2.3%; p = 0.0004), but lower specificity (-0.6%) and PPV (-3.9%) as well as higher recall rate (+ 0.6%) and arbitration rate (+ 2.2%; p < 0.0001 for all). Integrated AIspec showed no significant difference in any outcome measures apart from a slightly higher arbitration rate (p < 0.0001). Subgroup analyses showed higher detection of interval cancers by Standalone AI and Integrated AI at both thresholds (p < 0.0001 for all) with a varying composition of detected cancers across multiple subgroups of tumour characteristics.

CONCLUSIONS:

Replacing first reader in double reading with an AI could be feasible but choosing an appropriate AI threshold is crucial to maintaining cancer detection accuracy and workload.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Contexto em Saúde: 2_ODS3 Base de dados: MEDLINE Assunto principal: Neoplasias da Mama Limite: Female / Humans Idioma: En Revista: Cancer Imaging Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Contexto em Saúde: 2_ODS3 Base de dados: MEDLINE Assunto principal: Neoplasias da Mama Limite: Female / Humans Idioma: En Revista: Cancer Imaging Ano de publicação: 2023 Tipo de documento: Article