Your browser doesn't support javascript.
loading
Phosphorescence approach based on silica protected carbon dots for autofluorescence interference-free and highly selective detection of fluoride.
Liu, Meng-Xian; Chen, Xiao-Bing; Liu, Wen-Ye; Wang, Jian-Hua; Yu, Yong-Liang; Chen, Shuai.
Afiliação
  • Liu MX; Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Box 332, Shenyang, 110819, China.
  • Chen XB; Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Box 332, Shenyang, 110819, China.
  • Liu WY; Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Box 332, Shenyang, 110819, China.
  • Wang JH; Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Box 332, Shenyang, 110819, China.
  • Yu YL; Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Box 332, Shenyang, 110819, China. Electronic address: yuyl@mail.neu.edu.cn.
  • Chen S; Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Box 332, Shenyang, 110819, China. Electronic address: chenshuai@mail.neu.edu.cn.
Anal Chim Acta ; 1287: 342102, 2024 Jan 25.
Article em En | MEDLINE | ID: mdl-38182345
ABSTRACT

BACKGROUND:

Fluoride (F-), an anion with the smallest ionic radius and highest charge density, plays an important role in biomedical and environmental processes, making the development of accurate F- detection methods of great importance. Fluorometric methods with simplicity and sensitivity have gained considerable attention in F- detection. However, their accuracy faces challenges due to issues like autofluorescence interference during real-time light excitation and limited selectivity. Therefore, it is important to establish a simple, real-time light excitation-free, and highly selective method for the accurate determination of F- in complicated samples.

RESULTS:

Herein, a novel phosphorescent approach is developed for the selective and accurate detection of F- in complex samples. Phosphorescence emission CDs@SiO2 is fabricated by confining CDs in a silica protective layer. This design retains the favorable water solubility of silica while benefitting from its inertness, making it resistant to most substances. Furthermore, phosphorescent analysis without real-time light excitation eliminates autofluorescence interference, significantly improving the signal-to-noise ratio (SNR) and simplifying sample pretreatment. The specific interaction between F- and the Si-O bond can lead to the degradation of the silica protective layer, exposing the CDs to the solution, resulting in phosphorescence quenching, achieving the highly accurate and sensitive detection of F- with a linear range of 0.001-4 mM and a limit of detection (LOD) of 1 µM.

SIGNIFICANCE:

This novel F- phosphorescence method based on the metal-free phosphorescent nanomaterial CDs@SiO2 integrates the benefits of no autofluorescence interference, high selectivity, and full aqueous compatibility, and its combination with a smartphone provides a simple, portable, and cost-effective detection platform for accurate and highly sensitive determination of F- in complex samples.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: Anal Chim Acta Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: Anal Chim Acta Ano de publicação: 2024 Tipo de documento: Article