Your browser doesn't support javascript.
loading
CT-Based Screening for Pulmonary Metastases in Head and Neck Squamous Cell Cancers: Diagnostic Accuracy and Cost Comparison with PET-CECT.
Mahajan, Abhishek; Shukla, Shreya; Nandi, Debanjan; Sable, Nilesh; Ankathi, Suman Kumar; Vaish, Richa; Patil, Vasundhara; Sahu, Arpita; Bhattacharya, Kajari; Agarwal, Ujjwal; Pai, Prathamesh; Laskar, Sarbani Ghosh; Chaukar, Devendra; Prabhash, Kumar; Cruz, Anil D '; Patil, Asawari; Pantvaidya, Gouri; Noronha, Vanita; Patil, Vijay; Menon, Nandini; Thiagarajan, Shivakumar; Chaturvedi, Pankaj.
Afiliação
  • Mahajan A; The Clatterbridge Cancer Centre NHS Foundation Trust, Pembroke Place, Liverpool, L7 8YA UK.
  • Shukla S; Department of Radiodiagnosis, Tata Memorial Hospital, Homi Bhabha National Institute, Mumbai, 400 012 Maharashtra India.
  • Nandi D; Department of Radiodiagnosis, Tata Memorial Hospital, Homi Bhabha National Institute, Mumbai, 400 012 Maharashtra India.
  • Sable N; Department of Radiodiagnosis, Tata Memorial Hospital, Homi Bhabha National Institute, Mumbai, 400 012 Maharashtra India.
  • Ankathi SK; Department of Radiodiagnosis, Tata Memorial Hospital, Homi Bhabha National Institute, Mumbai, 400 012 Maharashtra India.
  • Vaish R; Department of Head and Neck Surgery, Tata Memorial Hospital, Homi Bhabha National Institute, Mumbai, 400 012 Maharashtra India.
  • Patil V; Department of Radiodiagnosis, Tata Memorial Hospital, Homi Bhabha National Institute, Mumbai, 400 012 Maharashtra India.
  • Sahu A; Department of Radiodiagnosis, Tata Memorial Hospital, Homi Bhabha National Institute, Mumbai, 400 012 Maharashtra India.
  • Bhattacharya K; Department of Radiodiagnosis, Tata Memorial Hospital, Homi Bhabha National Institute, Mumbai, 400 012 Maharashtra India.
  • Agarwal U; Department of Radiodiagnosis, Tata Memorial Hospital, Homi Bhabha National Institute, Mumbai, 400 012 Maharashtra India.
  • Pai P; Department of Head and Neck Surgery, Tata Memorial Hospital, Homi Bhabha National Institute, Mumbai, 400 012 Maharashtra India.
  • Laskar SG; Department of Pathology, Tata Memorial Hospital, Homi Bhabha National Institute, Mumbai, 400 012 Maharashtra India.
  • Chaukar D; Department of Head and Neck Surgery, Tata Memorial Hospital, Homi Bhabha National Institute, Mumbai, 400 012 Maharashtra India.
  • Prabhash K; Department of Medical Oncology, Tata Memorial Hospital, Homi Bhabha National Institute, Mumbai, 400 012 Maharashtra India.
  • Cruz AD'; Department of Head and Neck Surgery, Tata Memorial Hospital, Homi Bhabha National Institute, Mumbai, 400 012 Maharashtra India.
  • Patil A; Department of Pathology, Tata Memorial Hospital, Homi Bhabha National Institute, Mumbai, 400 012 Maharashtra India.
  • Pantvaidya G; Department of Head and Neck Surgery, Tata Memorial Hospital, Homi Bhabha National Institute, Mumbai, 400 012 Maharashtra India.
  • Noronha V; Department of Medical Oncology, Tata Memorial Hospital, Homi Bhabha National Institute, Mumbai, 400 012 Maharashtra India.
  • Patil V; Department of Medical Oncology, Tata Memorial Hospital, Homi Bhabha National Institute, Mumbai, 400 012 Maharashtra India.
  • Menon N; Department of Medical Oncology, Tata Memorial Hospital, Homi Bhabha National Institute, Mumbai, 400 012 Maharashtra India.
  • Thiagarajan S; Department of Head and Neck Surgery, Tata Memorial Hospital, Homi Bhabha National Institute, Mumbai, 400 012 Maharashtra India.
  • Chaturvedi P; Department of Head and Neck Surgery, Tata Memorial Hospital, Homi Bhabha National Institute, Mumbai, 400 012 Maharashtra India.
Indian J Surg Oncol ; 14(4): 881-889, 2023 Dec.
Article em En | MEDLINE | ID: mdl-38187855
ABSTRACT
This study's objective was to compare detection rates of radiograph, computed tomography (CT), and positron emission tomography-contrast-enhanced computed tomography (PET-CECT) for pulmonary metastasis/synchronous primary lung tumors in head and neck squamous cell cancer (HNSCC) and its association with clinico-radio-pathological factors. Our retrospective study included 837 HNSCC patients from January 2012 to December 2017. Lung nodules were characterized on CT as benign, indeterminate, and metastatic. The true detection rate and statistical significance of associated risk factors were calculated. Risk factors for metastasis were determined using univariate and multivariate logistic regression models. Seventy-five (8.9%) patients had pulmonary metastasis and 3 (0.3%) had second lung primary. Detection rate of pulmonary metastasis by CT was higher (sensitivity-97.3%, specificity-97.2%) as compared to radiograph (sensitivity 49% and specificity 89%). Correlation was found between pulmonary and extra-pulmonary metastasis and N classification (P = 0.01, P = 0.02) and positive low jugular node (P = 0.001, P = 0.001). Using PET-CECT in place of CT costed an extra outlay of 7,033,805 INR (95,551.85 USD) while detecting distant metastasis in only 4 (0.47%) extra cases. Chest CT is a useful pulmonary metastases screening tool in advanced HNSCC patients with reasonable imaging cost as compared to PET-CT.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Contexto em Saúde: 1_ASSA2030 Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies / Health_economic_evaluation / Observational_studies / Prognostic_studies / Risk_factors_studies / Screening_studies Idioma: En Revista: Indian J Surg Oncol Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Contexto em Saúde: 1_ASSA2030 Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies / Health_economic_evaluation / Observational_studies / Prognostic_studies / Risk_factors_studies / Screening_studies Idioma: En Revista: Indian J Surg Oncol Ano de publicação: 2023 Tipo de documento: Article