Automated three-dimensional image registration for longitudinal photoacoustic imaging.
J Biomed Opt
; 29(Suppl 1): S11515, 2024 Jan.
Article
em En
| MEDLINE
| ID: mdl-38223681
ABSTRACT
Significance:
Photoacoustic tomography (PAT) has great potential in monitoring disease progression and treatment response in breast cancer. However, due to variations in breast repositioning, there is a chance of geometric misalignment between images. Further, poor repositioning can affect light fluence distribution and imaging field-of-view, making images different from one another. The net effect is that it becomes challenging to distinguish between image changes due to repositioning effects and those due to true biological variations.Aim:
The aim is to develop a three-dimensional image registration framework for geometrically aligning repeated PAT volumetric images, which are potentially affected by repositioning effects such as misalignment, changed radiant exposure conditions, and different fields-of-view.Approach:
The proposed framework involves the use of a coordinate-based neural network to represent the displacement field between pairs of PAT volumetric images. A loss function based on normalized cross correlation and Frangi vesselness feature extraction at multiple scales was implemented. We refer to our image registration framework as MUVINN-reg, which stands for multiscale vesselness-based image registration using neural networks. The approach was tested on a longitudinal dataset of healthy volunteer breast PAT images acquired with the hybrid photoacoustic-ultrasound Photoacoustic Mammoscope 3 imaging system. The registration performance was also tested under unfavorable repositioning conditions such as intentional mispositioning, and variation in breast-supporting cup size between measurements.Results:
A total of 13 pairs of repeated PAT scans were included in this study. MUVINN-reg showed excellent performance in co-registering each pair of images. The proposed framework was shown to be robust to image intensity shifts and field-of-view changes. Furthermore, MUVINN-reg could align vessels at imaging depths greater than 4 cm.Conclusions:
The proposed framework will enable the use of PAT for quantitative and reproducible monitoring of disease progression and treatment response.Palavras-chave