Your browser doesn't support javascript.
loading
Coronary Flow Reserve and Myocardial Resistance Reserve Changes After Transcatheter Aortic Valve Implantation in Aortic Stenosis.
Gutiérrez-Barrios, Alejandro; Cañadas-Pruaño, Dolores; Alfaro, Luis Martin; Gheorghe, Livia; Silva, Etelvino; Noval-Morillas, Inmaculada; Pino, Carlos Campo-Cossio; Rueda, Ricardo Zayas; Calle-Pérez, Germán; Vázquez-García, Rafael; Toro-Cebada, Rocio.
Afiliação
  • Gutiérrez-Barrios A; Cardiology Department, Hospital Puerta del Mar, Cádiz, Spain; Instituto de Investigación e Innovación en Ciencias Biomédicas de Cádiz (INiBICA), University of Cadiz, Cadiz, Spain. Electronic address: aleklos@hotmail.com.
  • Cañadas-Pruaño D; Cardiology Department, Hospital Puerta del Mar, Cádiz, Spain; Instituto de Investigación e Innovación en Ciencias Biomédicas de Cádiz (INiBICA), University of Cadiz, Cadiz, Spain.
  • Alfaro LM; Cardiology Department, Hospital Puerta del Mar, Cádiz, Spain.
  • Gheorghe L; Cardiology Department, Hospital Puerta del Mar, Cádiz, Spain; Instituto de Investigación e Innovación en Ciencias Biomédicas de Cádiz (INiBICA), University of Cadiz, Cadiz, Spain.
  • Silva E; Instituto de Investigación e Innovación en Ciencias Biomédicas de Cádiz (INiBICA), University of Cadiz, Cadiz, Spain.
  • Noval-Morillas I; Cardiology Department, Hospital Puerta del Mar, Cádiz, Spain; Instituto de Investigación e Innovación en Ciencias Biomédicas de Cádiz (INiBICA), University of Cadiz, Cadiz, Spain.
  • Pino CC; Cardiology Department, Hospital Puerta del Mar, Cádiz, Spain.
  • Rueda RZ; Cardiology Department, Hospital Puerta del Mar, Cádiz, Spain; Instituto de Investigación e Innovación en Ciencias Biomédicas de Cádiz (INiBICA), University of Cadiz, Cadiz, Spain.
  • Calle-Pérez G; Cardiology Department, Hospital Puerta del Mar, Cádiz, Spain; Instituto de Investigación e Innovación en Ciencias Biomédicas de Cádiz (INiBICA), University of Cadiz, Cadiz, Spain.
  • Vázquez-García R; Cardiology Department, Hospital Puerta del Mar, Cádiz, Spain; Instituto de Investigación e Innovación en Ciencias Biomédicas de Cádiz (INiBICA), University of Cadiz, Cadiz, Spain.
  • Toro-Cebada R; Instituto de Investigación e Innovación en Ciencias Biomédicas de Cádiz (INiBICA), University of Cadiz, Cadiz, Spain.
Am J Cardiol ; 214: 109-114, 2024 03 01.
Article em En | MEDLINE | ID: mdl-38232809
ABSTRACT
Aortic valve stenosis (AS) induces an alteration in hemodynamic conditions that are responsible for coronary microvasculature impairment. Relief of AS by transcatheter aortic valve implantation (TAVI) is expected to improve the coronary artery hemodynamic. We aimed to assess the midterm effects of TAVI in coronary flow reserve (CFR) and myocardial resistance reserve (MRR) by a continuous intracoronary thermodilution technique. At-rest and hyperemic coronary flow was measured by a continuous thermodilution technique in 23 patients with AS and compared with that in 17 matched controls, and repeated 6 ± 3 months after TAVI in 11 of the patients with AS. In patients with AS, absolute coronary flow at rest was significantly greater, and absolute resistance at rest was significantly less, than in controls (p <0.01 for both), causing less CFR and MRR (1.73 ± 0.4 vs 2.85 ± 1.1, p <0.01 and 1.95 ± 0.4 vs 3.22 ± 1.4, p <0.01, respectively). TAVI implantation yielded a significant 35% increase in CFR (p >0.01) and a 39% increase in MRR (p <0.01) driven by absolute coronary flow at rest reduction (p = 0.03). In patients with AS, CFR and MRR determined by continuous thermodilution are significantly impaired. At 6-month follow-up, TAVI improves these indexes and partially relieves the pathophysiologic alterations, leading to a partial restoration of CFR and MRR.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Estenose da Valva Aórtica / Estenose Coronária / Reserva Fracionada de Fluxo Miocárdico / Substituição da Valva Aórtica Transcateter Limite: Humans Idioma: En Revista: Am J Cardiol Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Estenose da Valva Aórtica / Estenose Coronária / Reserva Fracionada de Fluxo Miocárdico / Substituição da Valva Aórtica Transcateter Limite: Humans Idioma: En Revista: Am J Cardiol Ano de publicação: 2024 Tipo de documento: Article