Your browser doesn't support javascript.
loading
Digital image determination of copper in food and water after preconcentration and magnetic tip separation for in-cavity desorption/color development.
Alharbi, Walaa; Alharbi, Khadijah H; Alotaibi, Abdullah A; Gomaa, Hassan E M; Abdel Azeem, Sami M.
Afiliação
  • Alharbi W; Department of Chemistry, Science and Arts College, King Abdulaziz University, 21911 Rabigh, Saudi Arabia. Electronic address: wnhalharbe@kau.edu.sa.
  • Alharbi KH; Department of Chemistry, Science and Arts College, King Abdulaziz University, 21911 Rabigh, Saudi Arabia. Electronic address: Khalharbe@kau.edu.sa.
  • Alotaibi AA; Department of Chemistry, College of Science and Humanities, Shaqra University, 11911, AdDawadimi, Saudi Arabia; Water Research Group, College of Science and Humanities at Ad-Dawadmi, Shaqra University, Ad-Dawadmi 11911, Saudi Arabia. Electronic address: aaalotaibi@su.edu.sa.
  • Gomaa HEM; Department of Chemistry, College of Science and Humanities, Shaqra University, 11911, AdDawadimi, Saudi Arabia; Department of Nuclear Safety Engineering, Nuclear Installations Safety Division, Atomic Energy Authority, Cairo 11765, Egypt; Water Research Group, College of Science and Humanities at Ad-
  • Abdel Azeem SM; Chemistry Department, Faculty of Science, Fayoum University, 35514 Fayoum, Egypt; Chemistry Department, Al-Quwayiyah College of Science and Humanities, Shaqra University, 11971, Kingdom of Saudi Arabia; Water Research Group, College of Science and Humanities at Ad-Dawadmi, Shaqra University, Ad-Dawa
Food Chem ; 442: 138435, 2024 Jun 01.
Article em En | MEDLINE | ID: mdl-38266415
ABSTRACT
A new analytical method for measuring copper in food and water was developed and validated, employing a solid-phase extraction (SPE) technique combined with digital-image-based (DIB) detection. A novel magnetic adsorbent of zinc ferrite/Citrullus colocynthis biochar (ZF@C.BC) was used to preconcentrate copper. A magnetic tip was used to separate the copper-loaded adsorbent from the extraction medium and to dispense it to the DIB plate. In-situ desorption and development of the spot color with iodide-starch reagent were carried out, and a digital image of the developed spots was captured using a smartphone and processed using ImageJ software. The copper adsorption capacity was 91.3 mg g-1. Desorption was effected using a 0.3 mol L-1 hydrochloric acid. The preconcentration factor was 300, the limit of detection was 4.8 µg L-1, the linearity was 16-600 µg L-1 and the sample throughput was 12 h-1. The developed approach was validated by analyzing food and water samples, confirming recoveries ≥ 91 % and 88 %, respectively, with RSD ≤ 8.4 %, n = 3.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Água / Cobre Idioma: En Revista: Food Chem Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Água / Cobre Idioma: En Revista: Food Chem Ano de publicação: 2024 Tipo de documento: Article