On the importance of fundamental computational fluid dynamics toward a robust and reliable model of left atrial flows.
Khalili, Ehsan; Daversin-Catty, Cécile; Olivares, Andy L; Mill, Jordi; Camara, Oscar; Valen-Sendstad, Kristian.
Afiliação
  • Khalili E; Department of Computational Physiology, Simula Research Laboratory, Oslo, Norway.
  • Daversin-Catty C; Department of Numerical Analysis and Scientific Computing, Simula Research Laboratory, Oslo, Norway.
  • Olivares AL; Department of Information and Communication Technologies, Universitat Pompeu Fabra, Barcelona, Spain.
  • Mill J; Department of Information and Communication Technologies, Universitat Pompeu Fabra, Barcelona, Spain.
  • Camara O; Department of Information and Communication Technologies, Universitat Pompeu Fabra, Barcelona, Spain.
  • Valen-Sendstad K; Department of Computational Physiology, Simula Research Laboratory, Oslo, Norway.
Int J Numer Method Biomed Eng ; 40(4): e3804, 2024 Apr.
Article em En | MEDLINE | ID: mdl-38286150
ABSTRACT
Computational fluid dynamics (CFD) studies of left atrial flows have reached a sophisticated level, for example, revealing plausible relationships between hemodynamics and stresses with atrial fibrillation. However, little focus has been on fundamental fluid modeling of LA flows. The purpose of this study was to investigate the spatiotemporal convergence, along with the differences between high- (HR) versus normal-resolution/accuracy (NR) solution strategies, respectively. Rigid wall CFD simulations were conducted on 12 patient-specific left atrial geometries obtained from computed tomography scans, utilizing a second-order accurate and space/time-centered solver. The convergence studies showed an average variability of around 30% and 55% for time averaged wall shear stress (WSS), oscillatory shear index (OSI), relative residence time (RRT), and endothelial cell activation potential (ECAP), even between intermediate spatial and temporal resolutions, in the left atrium (LA) and left atrial appendage (LAA), respectively. The comparison between HR and NR simulations showed good correlation in the LA for WSS, RRT, and ECAP ( R 2 > .9 ), but not for OSI ( R 2 = .63 ). However, there were poor correlations in the LAA especially for OSI, RRT, and ECAP ( R 2 = .55, .63, and .61, respectively), except for WSS ( R 2 = .81 ). The errors are comparable to differences previously reported with disease correlations. To robustly predict atrial hemodynamics and stresses, numerical resolutions of 10 M elements (i.e., Δ x = ∼ .5 mm) and 10 k time-steps per cycle seem necessary (i.e., one order of magnitude higher than normally used in both space and time). In conclusion, attention to fundamental numerical aspects is essential toward establishing a plausible, robust, and reliable model of LA flows.