Your browser doesn't support javascript.
loading
Articulating Video Stylet Compared to Other Techniques for Endotracheal Intubation in Normal Airways: A Simulation Study in Consultants with No Prior Experience.
Messina, Simone; Merola, Federica; Santonocito, Cristina; Sanfilippo, Marco; Sanfilippo, Giulia; Lombardo, Federica; Bruni, Andrea; Garofalo, Eugenio; Murabito, Paolo; Sanfilippo, Filippo.
Afiliação
  • Messina S; Department of Anaesthesia and Intensive Care, Policlinico-San Marco University Hospital, Via S. Sofia n 78, 95123 Catania, Italy.
  • Merola F; School of Anesthesia and Intensive Care, University "Magna Graecia", 88100 Catanzaro, Italy.
  • Santonocito C; Department of Anaesthesia and Intensive Care, Policlinico-San Marco University Hospital, Via S. Sofia n 78, 95123 Catania, Italy.
  • Sanfilippo M; Department of Anaesthesia and Intensive Care, Policlinico-San Marco University Hospital, Via S. Sofia n 78, 95123 Catania, Italy.
  • Sanfilippo G; School of Anesthesia and Intensive Care, University "Magna Graecia", 88100 Catanzaro, Italy.
  • Lombardo F; School of Anesthesia and Intensive Care, University "Magna Graecia", 88100 Catanzaro, Italy.
  • Bruni A; Department of Anaesthesia and Intensive Care, Policlinico-San Marco University Hospital, Via S. Sofia n 78, 95123 Catania, Italy.
  • Garofalo E; School of Anesthesia and Intensive Care, University "Magna Graecia", 88100 Catanzaro, Italy.
  • Murabito P; School of Anesthesia and Intensive Care, University "Magna Graecia", 88100 Catanzaro, Italy.
  • Sanfilippo F; School of Anesthesia and Intensive Care, University "Magna Graecia", 88100 Catanzaro, Italy.
J Clin Med ; 13(3)2024 Jan 26.
Article em En | MEDLINE | ID: mdl-38337422
ABSTRACT
Simulation for airway management allows for acquaintance with new devices and techniques. Endotracheal intubation (ETI), most commonly performed with direct laryngoscopy (DL) or video laryngoscopy (VLS), can be achieved also with combined laryngo-bronchoscopy intubation (CLBI). Finally, an articulating video stylet (ProVu) has been recently introduced. A single-center observational cross-sectional study was performed in a normal simulated airway scenario comparing DL, VLS-Glidescope, VLS-McGrath, CLBI and ProVu regarding the success rate (SR) and corrected time-to-intubation (cTTI, which accounts for the SR). Up to three attempts/device were allowed (maximum of 60 s each). Forty-two consultants with no experience with ProVu participated (15 ± 9 years after training completion). The DL was significantly faster (cTTI) than all other devices (p = 0.033 vs. VLSs, and p < 0.001 for CLBI and Provu), no differences were seen between the two VLSs (p = 0.775), and the VLSs were faster than CLBI and ProVu. Provu had a faster cTTI than CLBI (p = 0.004). The DL and VLSs showed similar SRs, and all the laryngoscopes had a higher SR than CLBI and ProVu at the first attempt. However, by the third attempt, the SR was not different between the DL/VLSs and ProVu (p = 0.241/p = 0.616); ProVu was superior to CLBI (p = 0.038). In consultants with no prior experience, ProVu shows encouraging results compared to DL/VLSs under simulated normal airway circumstances and further studies are warranted.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Observational_studies Idioma: En Revista: J Clin Med Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Observational_studies Idioma: En Revista: J Clin Med Ano de publicação: 2024 Tipo de documento: Article