Your browser doesn't support javascript.
loading
Pulse-wave analysis during routine blood pressure measurement shows potential to distinguish between sinus and nonsinus rhythm.
Yang, Chung-Chun; Chan, I-Ping; Hsueh, Tung; Lin, Shiun-Long.
Afiliação
  • Yang CC; Veterinary Medical Teaching Hospital, National Chung Hsing University, Taichung, Taiwan.
  • Chan IP; Veterinary Medical Teaching Hospital, National Chung Hsing University, Taichung, Taiwan.
  • Hsueh T; Veterinary Medical Teaching Hospital, National Chung Hsing University, Taichung, Taiwan.
  • Lin SL; Veterinary Medical Teaching Hospital, National Chung Hsing University, Taichung, Taiwan.
Am J Vet Res ; 85(5)2024 May 01.
Article em En | MEDLINE | ID: mdl-38422616
ABSTRACT

OBJECTIVE:

To investigate whether pulse-wave analysis (PWA) performed by trained evaluators facilitates detection of nonsinus rhythm. ANIMALS Same-day, high-definition oscillometry pulse-wave data and ECG results of 155 animals (144 dogs and 11 cats) were analyzed.

METHODS:

In this cross-sectional study, we enrolled 18 participants from various backgrounds, all of whom received PWA training. The ability to distinguish between sinus and nonsinus rhythms was assessed using receiver operating characteristic curve analysis. The pulse-wave datasets were divided into 5 ECG categories. Agreement between ECG diagnoses and PWA-based arrhythmia detection was evaluated using Cohen κ values, and the correlation between the academic year of veterinary students and their κ values was assessed.

RESULTS:

All cardiology researchers demonstrated satisfactory accuracy in distinguishing pathological rhythms using PWA (area under the curve, 0.704 to 0.761), with the highest accuracy in detecting atrial fibrillation (area under the curve, 0.811 to 0.845). Fair agreement with ECG categorization was achieved by all 3 cardiology researchers, 2 of 5 general practitioners, and 3 of 10 veterinary undergraduates. The veterinary undergraduates' years of study were correlated with their diagnostic performance (Spearman ρ = 0.658; P = .019). CLINICAL RELEVANCE PWA during routine noninvasive blood pressure measurement showed significant potential for the detection of pathological arrhythmias, notably atrial fibrillation. This approach yielded improved effectiveness when it was used by veterinarians with cardiology experience. Thus, introducing hands-on training courses, particularly those focused on cardiology and interactive workshops, may enable frontline veterinarians to promptly identify arrhythmias using PWA, facilitating timely ECG examinations or referrals.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Arritmias Cardíacas / Doenças do Gato / Doenças do Cão / Eletrocardiografia / Análise de Onda de Pulso Limite: Animals / Female / Humans / Male Idioma: En Revista: Am J Vet Res Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Arritmias Cardíacas / Doenças do Gato / Doenças do Cão / Eletrocardiografia / Análise de Onda de Pulso Limite: Animals / Female / Humans / Male Idioma: En Revista: Am J Vet Res Ano de publicação: 2024 Tipo de documento: Article